Thermal and electrical properties
Power supply
Permitted range
Power supply
20 V input voltage on the reader, typical
24 V input voltage on the reader, typical
30 V input voltage on the reader, typical
Power supply
20 V input voltage on the reader, typical
24 V input voltage on the reader, typical
30 V input voltage on the reader, typical
Rampup time
All supply and signal voltages must be safety extra low voltage (SELV/PELV according to EN 60950)
1)
24 VDC supply: safe (electrical) isolation of extra-low voltage (SELV / PELV acc. to EN 60950)
Mechanical environmental conditions
Shock resistant acc. to EN 60068-2-27
Vibration acc. to EN 60068-2-6
Climatic conditions
Ambient temperature during operation
Ambient temperature for transport and storage
The values for shock and vibration are maximum values and must not be applied continuously.
1)
EMC & approvals/conformity for ETSI variant
Electromagnetic compatibility
Approvals/Conformity

SIMATIC RF600

System Manual, xx/2014, J31069-D0171-U001-A15-7618
21.6 to 30 VDC
1
Current consumption
(in standby mode, no
transmit power)
135 mA
115 mA
95 mA
Current consumption
(at 500 mW ERP)
470 mA
395 mA
320 mA
7 s
50 g
1
20 g
1
-25 °C to +55 °C
(a 10-minute warm-up time must be allowed at an operating
temperature below -20 °C)
-40 °C to +85 °C
ETSI EN 301 489-1 / -3
ETSI EN 302 208 V1.3.1
ETSI EN 302 208 V1.4.1
Radio acc. to R&TTE guidelines, EN 301 489
CE
ETSI EN 302-208 V1.1.1
ETSI EN 302-208 V1.3.1
ETSI EN 302-208 V1.4.1
Reader degree of protection acc. to EN 60529 (IP65)
Readers
5.3 RF630R reader
Current consumption
(in standby mode, no
transmit power)
2.7 W
2.76 W
2.85 W
Power requirement
(at 500 mW ERP)
9.4 W
9.48 W
9.6 W