Configuration/Integration - Siemens Simatic RF600 System Manual

Hide thumbs Also See for Simatic RF600:
Table of Contents

Advertisement

Mounting/installing the device
You can mount the reader in two different ways:
● Via a standardized VESA 100 mounting system using the Antenna Mounting Kit (see
Chapter Mounting with antenna mounting kit (Page 331)). Tighten the M4 screws on the
rear of the reader using a maximum torque of ≤ 1.3 Nm.
● Directly onto a flat surface.
The positions of the fixing holes for the device are shown in the section Dimension drawings
(Page 108).
5.2.4

Configuration/integration

The RS422 system interface is provided for integrating the device into system
environments/networks. The system interface transfers data to SIMATIC controllers or PCs
with the appropriate interface.
Apart from transmitting communication data from the reader to the controller and vice versa,
the RS422 interface also supplies power to the reader (24 V DC).
Figure 5-5
The RF620R reader can alternatively be connected to a SIMATIC controller via the ASM
456, ASM 475, RF170C and RF180C interface modules/communication modules.
The RF620R reader can alternatively also be connected directly to the PC via the RF182
communication module.
For further details on the interface modules used, see Chapter Auto-Hotspot .
Further information about commissioning the readers can be found in the configuration
manual "RF620R/RF630R" in the "Commissioning" section.
SIMATIC RF600
System Manual, xx/2014, J31069-D0171-U001-A15-7618
Overview of configuration of the RF620R reader
Readers
5.2 RF620R reader
103