RF600 system planning
4.3 Antenna configurations
Antenna configuration 3
Antenna configuration 4
46
Description/ application areas
Preferred for the identification of goods
at loading gates: The transponder is
located in the radiation field of two
antennas; for reliable transponder
reading, the height of the transponders
above floor level must therefore be
known with reasonable accuracy.
Transponder
Description/ application areas
Preferred for the identification of goods
at loading gates: Similar to configuration
2, but with additional reading reliability
when the transponder is at an angle to
the vertical.