Sequence program
G.OGSTOR instruction
Completion device (D)
Status display device
at completion (D)+1
App - 17
(1)
Functions
(a)
Restores the offset/gain values of the user range setting stored in the CPU
to the D/A converter module.
(b)
There are two types of interlock signals for the G(P).OGSTOR instruction:
the completion device (D) and the status display device at completion (D) +
1.
1)
Completion device
Turns on in the END processing of the scan where the G(P).OGSTOR
instruction is completed, and turns off in the next END processing.
2)
Status display device at completion
Turns on and off depending on the completion status of the
G(P).OGSTOR instruction.
Normal completion
Abnormal completion : Turns on in the END processing of the scan
END processing
END processing
ON
OFF
OFF
OFF
(c)
When the offset/gain values are restored, the reference accuracy falls to
about less than three times of the accuracy before that.
(2)
Operation error
In any of the following cases, an error occurs and the corresponding error codes
are stored into the completion status area (S)+1.
Error code
The G(P).OGSTOR instruction was executed in the offset/gain setting
161
mode.
162
The G(P).OGSTOR instruction was executed consecutively.
The G(P).OGSTOR instruction was executed for the model that differs
163
from the model for which the G(P).OGLOAD instruction had been
executed.
: Stays off and does not change.
where the G(P).OGSTOR instruction is
completed, and turns off in the next END
processing.
Execution completion of
the G.OGSTOR instruction
Case resulting in operation error
MELSEC-Q
END processing END processing
ON
ON Abnormal
completion
Normal completion
1 scan