3 Technical specifications
3.4

Electrical diagram

Fig.2
Electrical diagram
X01
X02
1
-
7
1
-
X012
X013
X022
X021
2
7
3
4
X011
X20
X0141
6
X014
X015
5
230V, 50Hz
X016
X017
X020
X018
230VAC
20
X019
CB-01
1
-
7
X4
F1
6.3 AT
X1
X2
Pump
1
2
3
N
L
1
2
3
1 Control unit (CU-GH)
2 Lighting
3 Ignition pin
4 Ignition transformer
5 On/off switch
6 Power supply
7 Service connector / computer connection
8 Control panel
9 Fan supply
10 Storage parameter
11 Flow sensor
16
X03
1
9
1
-
15
X041 X051 X053 X054 X055 X081
9
10
11
8
X202
X201
EMC
X031
X032
X033
X035
X039
X036
1
-
7
1
-
15
X5
X6
X3
PWM
0 - 10
On/off
0
+
0
+
Tout
OT
BL
RL
1
2
3
4 5 6 7 8 9 10 11 12
CU-GH & HMI
X04 / X05
X06
1
-
15
1
-
4
12
13
14
15
X06
X07
X04 / X05
X03
X08
X09
X10
X11
X12
X037
Bus
X9
X4
X5
X1
X6
X2
X8
X3
X10
12 Heat exchanger sensor
13 Return sensor
14 Hydraulic pressure sensor
15 Air pressure differential switch
16 Flue gas sensor
17 Fan control (PWM)
18 Gas valve 1
19 Gas valve 2
20 Standard PCB
21 L-bus connections for additional PCBs
X07
X08
X09
X10
1
-
4
1
-
13
1 - 4
1 - 4
X071
X083
16
17
X02
X01
21
21
X038
Bus
7625116 - v.04 - 17012017
X11
X12
1 - 4
1
-
5
X121
X122
18
19
AD-0000669-05