Troubleshooting (Motion Detector) - Zublin MZ5000 Operating Instructions Manual

Motion detector
Table of Contents

Advertisement

Troubleshooting (detector)
Fault
Electric load does not
Switches on and off - Check coverage area for something causing the
without reason or does not
Switches during power switch - Install a varistor between
pulses:
Light switches off
despite someone
being in the coverage area:
Switches on during the day:
Following connection to the power supply:
The electronic system requires approx. one to two minutes before
it is ready for operation.
24
Cause/repair
- Twilight value set too high switch:
- Check the light's lamp
- Check positioning of the manual switch
- Check mains power supply/fuse
fault: drafts, animals, heating, switch off
again: etc. can all cause an error to
occur!
- Range too high, adjust the range using
the Tilt (L/R) controller and/or cover the
area of the lens causing the fault with
adhesive tape. Set the sensitivity to
medium or low.
- Check distance to the light (heat
reflections or direct effects of the light)
- For current transformers, relays and
electronic ballast OR for several parallel
detectors, connect the RC element in
parallel to the connected load.
the phase and neutral conductor.
Set the Time 1 potentiometer
(time delay) to a higher
value
Twilight value is set too high
(set the lux potentiometer on the moon
settings)
Please note: When the Twilight value
changes, the electronic system requires
approx. 1 minute before the newly
selected value is active!

Advertisement

Table of Contents
loading

Table of Contents