Connection, Diagrams Page 7 - Zublin MZ5000 Operating Instructions Manual

Motion detector
Table of Contents

Advertisement

Diagrams
Several motion detectors (max. three to four) including a short pulse
function (SP) control the staircase timer switch, time relay (door bell,
etc.)
Parallel switching of several motion detectors including additional
switch for continuous light.
We recommend switching a maximum of three to four motion detectors
in parallel, if the number of switching cycles is above average or in the
event of increased (inductive) loads, we recommend using the short
pulse function on the motion detector and switching the load via an
external staircase timer switch or contactor.
Connection of a RC element (between the neutral conductor and
switched phase) for peak voltages or interferences caused by parallel
connection of energy-savings lights, relays and electronic ballasts.
Varistor (between the neutral conductor and the phase) for peak
voltages when the motion detector switches on during supply switching
pulses, etc.