Download Print this page

Zublin Swiss Garde 4000 User Manual

120/240/300° outdoor motion detector

Advertisement

Quick Links

User Manual
120/240/300° Outdoor Motion Detector
Swiss Garde 4000

Advertisement

loading

Summary of Contents for Zublin Swiss Garde 4000

  • Page 1 User Manual 120/240/300° Outdoor Motion Detector Swiss Garde 4000...
  • Page 2 Warning! - Any work on the main power supply must only be completed by trai- ned specialists. - The product must be installed in accordance with installation guideli- nes/standards specific to your country. - Disconnect the 230V power supply before starting the installation process.
  • Page 3 In case of such an application, the lens should be covered with the louvre clips included in the scope of supply (see picture on page 4). 360° ceiling mount detection area Swiss Garde 4000-240° + SG 4000-300° 360° detection area, ideal in garages, corridors, etc. Pet tolerance functionality deactivated.
  • Page 4 Mounting socket Louvre clips Use to cover up unwanted detection areas Installation Wire the detector as follows: phase/outer conductor (L) brown; neutral/neutral conductor (N) blue; switching output / switched phase/ outer conductor (L’) red The removal of bridge L/D1 makes contact D1/D2 potential free. Optional: remote switching (R) via (supply of the phase) impulse switch (no neon bulbs!).
  • Page 5 Connecting electrical loads High inrush currents will considerably shorten the lifetime of the detector’s in-built relay. Please verify the technical data provided by the lamp or luminaires manufacturer concerning inrush currents, specifically with compact fluorescent, fluorescent lamps, electronic ballast, etc. in order not to overload the internal relay. We recommend connecting a maximum of three to four motion detectors in parallel.
  • Page 6 (switch-off sparks) or by several detectors connected in parallel (caused by capacitive current in the wires). Varistor (between neutral conductor (N) und phase (L)) to reduce mains voltage peaks. Swiss Garde 4000 end-user remote control standard detection pet tolerance functionality, animals will not be detected, creep zone protection deactivated, sensitivity reduction (see detection area on p.
  • Page 7 Controls LED, flashing once upon detection, three times upon adjusting TIME or LUX values, or receiving a command from the remote control. Accessory: maintenance remote Attention! LUX or TIME value adjustments during a stable working condition will be stored and become valid immediately. Any values adjusted by remote control will be overridden.
  • Page 8: Top View

    Detection range The 300°/240°/120° detection range with 360° creep zone protection as well as the tight detection area allow for an optimal function. The range depends on the installation height and walking direction (high sensitivity when cutting or changing a switching segment). Since the detector reacts to temperature differences between heat source and ambient temperature, the response may vary depending on the installation site (floor heating, hot environment, etc.).
  • Page 9 Troubleshooting error cause/amendment light does not turn on: - twilight adjustment value too low - connected lamp defective - check mains power / fuses detector triggers without reason - check detection area for potential reason / light never turns off: causes of false triggering: draught, heating, etc.
  • Page 10 Technical data 230V ± 10 % / 50Hz Nominal power: 2000W / 8.7A max. (cos φ = 1) Switching power: 1000VA / 4.35A max. inductive (cos φ = 0,5) potential-free relay Time adjustment: short impulse approx. 1 sec. (with 20 or 60 sec.