High Temp. Multi-Conductor Cable With M16 Connector (E-2Ccbxx); Figure 43: High Temp. Multi-Conductor Cable With M16 Connector (E-2Ccbxx) - Fluke Endurance Series User Manual

Innovative high temperature fiber optic infrared pyrometers
Hide thumbs Also See for Endurance Series:
Table of Contents

Advertisement

9.1.1. High Temp. Multi-conductor cable with M16 connector (E-2CCBxx)

Use the High Temp. 12-wire multi conductor cable (E-2CCBxx) for wiring the Endurance
sensor with the 24 VDC power supply, all inputs, outputs, and the RS485 interface. It is a
shielded 12-conductor cable, made of 2 twisted pairs plus 8 separate wires, equipped with a
M16 DIN connector on one side and wire sleeves at the counter side. The cable is Teflon coated
and withstands ambient temperatures from -80 to 200°C (-112°F to 392°F). Teflon coated
temperature cables have well to excellent resistance to oxidation, heat, weather, sun, ozone,
flame, water, acid, alkalis, and alcohol, but poor resistance to gasoline, kerosene, and
degreaser solvents.
Purchasable High Temp. 12-wire multi-conductor cables lengths are 4m (13ft.), 8m (26ft.), 15m
(50ft.), 30m (100ft.), 60m (200ft.), see Table 5.
Temperature:
Cable material
Cable diameter:
Conductors:
Power supply
Conductor:
Isolation:
Shield:
RS485 interface
Conductor:
Isolation:
Shield:
Outputs and Ground
Conductor:
Isolation:
Shield:
Teflon develops poisonous gasses, when it is exposed to flames!
If you cut the cable to shorten it, notice that both sets of twisted-pair wires
have drain wires inside their insulation. These drain wires (and the white wire
that is not part of the twisted pair) must be connected to the terminal labeled
CLEAR.
If you purchase your own High Temp. Multi-conductor cable, use wire with the
same specifications as herein mentioned. Maximum RS485 cable length is
1.200 m (4000 ft). Power supply (24VDC) feed in distance to the Endurance
sensor should not extend the 60m (200 ft.) limit.
An ordered Multi-Conductor Cable does not include a terminal block!

Figure 43: High Temp. Multi-Conductor Cable with M16 Connector (E-2CCBxx)

Innovative High Temperature Fiber Optic Infrared Pyrometers
UL-rated at -80 to 200°C (-112°F to 392°F)
Teflon
7 mm (0.275 in) nominal
2 wires (black/red)
0.3 mm² (AWG 22), stranded tinned copper
FEP 0.15 mm wall (0.006 in)
none
2 twisted pairs (black/white and purple/gray)
0,22 mm² (AWG 24), stranded tinned copper
FEP 0.15 mm wall (0.006 in)
Aluminized Mylar with drain wire
6 wires (green/brown/blue/orange/yellow/clear)
0,22 mm² (AWG 24), stranded tinned copper
FEP 0.15 mm wall (0.006 in)
none
Accessories
®
®
65

Advertisement

Table of Contents
loading

Table of Contents