Advertisement

TS
44DLX
Deluxe Test Set
Users Guide
PN 2460853
October 2005
©2005 Fluke Corporation. All rights reserved. Printed in China.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke TS44DLX

  • Page 1  44DLX Deluxe Test Set Users Guide PN 2460853 October 2005 ©2005 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies.
  • Page 2 MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ..............................1 Registration ............................... 1 Contacting Fluke Networks ..........................1 Safety Information ............................2 Design Features ..............................2 Physical Characteristics ............................. 2 Housing ..............................2 Belt Clips ..............................2 Line Cords ..............................3 Battery ................................ 3 Speaker and Speakerphone Microphone ....................
  • Page 4 TS44DLX Deluxe Test Set Users Guide Speaker Timeout ..........................14 Factory Defaults ..........................15 Maintenance ..............................15 Replacing the Battery ..........................15 Replacing or Relocating the Belt Clip .......................16 Replacing the Line Cord ..........................16 Removing the Old Line Cord ......................17 Installing a New Line Cord .........................18 Accessories ..............................19...
  • Page 5: Introduction

    ® 44DLX Deluxe Test Set Introduction Contacting Fluke Networks The TS44DLX Deluxe Test Set is an analog test www.flukenetworks.com telephone used by installers, repair technicians and support@flukenetworks.com other authorized personnel to test copper wire voice +1-425-446-4519 subscriber lines. In addition to providing standard off- hook operations, such as dialing and voice •...
  • Page 6: Safety Information

    Before you use the test set, inspect the case. Look for cracks or missing plastic. Pay The TS44DLX Deluxe Test Set housing is made of high- particular attention to the insulation impact plastic. The test set provides rugged service and surrounding the connectors.
  • Page 7: Line Cords

    Physical Characteristics bfp01.eps Figure 1. Physical Characteristics Line Cords The test set’s battery compartment makes battery replacement easy. See “Replacing the Battery” on page See Figure 1. The test set has a field replaceable line cord. The line Note cord is attached through a rubber strain relief at the If the test set fails to operate properly, first transmitter end of the test set.
  • Page 8: Speaker And Speakerphone Microphone

    Use the same battery if you know it the audio control keys. is good or use a new battery if you are not sure. If it still doesn’t work, contact Fluke Networks Technical Warning Support. Never hold the speaker against your ear when it is on, or when turning it on or off.
  • Page 9 Physical Characteristics Table 1. Test Set Audio Control Keys Description (refer to Figure 2) MUTE The MUTE key functions only when the test set is off-hook. When the test set is off-hook and being used as a handset, pressing the MUTE key shuts off the handset’s microphone. This is useful in noisy environments such as near heavy traffic.
  • Page 10 TS44DLX Deluxe Test Set Users Guide bfp03.eps Figure 3. TS44DLX Deluxe Keypad and Overlay Table 2. Test Set Keypad Control and Indicators Key or Indicator Description (refer to Figure 3) Numeric The numeric keypad is used to dial telephone numbers and make function selections. The numeric ∗...
  • Page 11 Physical Characteristics Table 2. Test Set Keypad Control and Indicators (continued) Key or Indicator Description (refer to Figure 3) STORE/PROG The STORE/PROG key is used for storing speed dialing numbers and for programming special test set functions. TONE/PULSE The TONE/PULSE key switches the test set between tone and pulse dialing. The TONE/PULSE key is active only when the test set is off-hook.
  • Page 12 POL/LO mA Notes (Polarity/ low The TS44DLX Deluxe Test Set is not polarity sensitive, and will function in either polarity. mA) LEDs The POL LEDs will not light if the test set is on-hook or when the speaker is on.
  • Page 13: Operation

    Operation Operation In the Monitor mode, the test set is typically used for one or more of the following procedures: The test set has two basic modes of operation: Talk • Verification that a line is idle when looking for a mode and Monitor mode.
  • Page 14: Disconnecting A Call

    Note When the test set is locked out, it remains on-hook, it The TS44DLX Deluxe will not go off-hook if the does not draw direct current from the line, and it line voltage exceeds 140 Vdc.
  • Page 15: Data Lockout Override Operation

    Operation Data detection is a two part process. The first part Data Lockout Override Operation requires listening to the line for audible data traffic in Normally, when the test set detects data, it means the Monitor mode as described above. If the line is quiet, operator has accidentally connected to a high-speed then the second part is to use the test set’s data detect data line and should immediately disconnect from the...
  • Page 16: High Voltage Lockout Operation

    When a While in Monitor mode, the test set allows the storage TS44DLX Deluxe is connected to a Tip and Ring pair of ten speed dialing numbers in ten memory locations with its Talk/Monitor switch in the T position, it (0 through 9).
  • Page 17: Storing The Last Number Dialed

    Operation Storing the Last Number Dialed Dialing a Stored Number If you dial a number then go on-hook and then decide Connect the test set to a working telephone line. you want to save that number in speed dialing Set the Talk/Monitor switch to T. memory, do the following: When the test set goes off-hook, press RCL Set the Talk/Monitor switch to M.
  • Page 18: Pause Duration

    TS44DLX Deluxe Test Set Users Guide Pause Duration Speaker Timeout The PBX Pause feature lets you insert a delay into The speaker draws more current from the battery than speed dialing numbers. This is required when dialing any other circuit on the test set. The battery drains out through a system that provides a second dial tone quickly when the speaker is left on continuously.
  • Page 19: Factory Defaults

    Maintenance Replacing the Battery Factory Defaults See Figure 4. The Restore Defaults function lets you restore all programmable features to their original factory To replace the 9 V battery: settings. This function does not clear stored telephone numbers. The defaults are: Caution •...
  • Page 20: Replacing Or Relocating The Belt Clip

    Place the belt clip on the test set and secure with to one of two locations. To order a replacement belt the screw supplied with the belt clip. clip, contact your local Fluke Networks authorized distributor. Place the blank insert in the belt clip slot that is not being used.
  • Page 21: Removing The Old Line Cord

    Maintenance Removing the Old Line Cord To remove the old line cord: Caution Be sure to account for all hardware removed. Loose or missing hardware could create a hazard for the end user. Notes Battery cover screws are retained in the cover and will not come all the way out of the battery cover.
  • Page 22: Installing A New Line Cord

    TS44DLX Deluxe Test Set Users Guide Installing a New Line Cord To install a new line cord on either model: From the outside of the housing, slide the screw lugs of a new line cord through the hole in the end of the test set housing.
  • Page 23: Accessories

    Specifications Accessories DTMF Output To order accessories, contact your local Fluke Networks Tone Frequency ±1.5 % maximum distributor. Error Tone Level -3 dBm combined (typical) Fluke High versus Low 2 dB ± 2 dB Networks Tone Difference Description Model Number...

Table of Contents