VEGABAR 66 • 4 ... 20 mA/HART
4.3 Mounting steps with straining clamp
Fig. 6: Straining clamp
1
Suspension cable
2
Suspension opening
3
Clamping jaws
Mount VEGABAR 66 with straining clamp as follows:
Hang the straining clamp on a suitable wall hook
1
Lower VEGABAR 66 to the requested height
2
Slide the clamping jaws upward and push the suspension cable
3
between them
Hold the suspension cable, push the clamping jaws downward
4
and fix them with a light blow
Removal is carried out in reverse order.
4 Mounting
1
2
3
15