State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 48:33:43:2d:46:43:1B:1B
Priority: 128
Domain ID: 11
Configuration information:
Domain configure: Enabled
Domain auto-reconfigure: Disabled
Fabric name: 48:33:43:2d:46:43:1A:1A
Priority: 128
Domain ID: 11 (preferred)
Principal switch running time information:
Priority: 1
Path
Interface
Upstream
Fc1/0/1
Downstream
Fc1/0/2
The output shows that:
The domain configuration was complete.
The principal switch assigned domain ID 1 1 to Switch A.
# Display the domain ID list of VSAN 1.
[SwitchA-vsan1] display fc domain-list vsan 1
Domain list of VSAN 1:
Number of domains: 4
Domain ID
WWN
0x01(1)
48:33:43:2d:46:43:1B:1B [Principal]
0x0b(11)
48:33:43:2d:46:43:1A:1A [Local]
0x0d(13)
48:33:43:2d:46:43:1C:1C
0x0e(14)
48:33:43:2d:46:43:1D:1D
The output shows that Switch B became the principal switch and assigned the smallest domain ID