HP 5920 SERIES Fc And Fcoe Configuration Manual page 37

Hide thumbs Also See for 5920 SERIES:
Table of Contents

Advertisement

receiving a keepalive frame, the switch maintains the status of the virtual link. If the switch fails to
receive a keepalive frame within 2.5 FKA advertisement intervals, it deletes the virtual link.
When configuring an FKA advertisement interval value on an FCF or NPV switch, use
reference to avoid service disruption.
Table 2 Recommended values for different application scenarios
Recommended
Application scenarios
value
Less than 90
Connected to servers, storage
seconds
devices, or third-party switches.
Active/standby switchover on
the switch takes more than 2.5 x
60 seconds because of the
amount of FCoE configuration.
60–90 seconds
ISSU reboot on an IRF member
switch with subordinate
switches takes more than 2.5 x
60 seconds because of the
amount of FCoE configuration.
ISSU reboot on a switch
operating in standalone mode
300–600
or in IRF mode but without
seconds
subordinate switches and
connecting to no nodes.
To configure an FKA advertisement interval value:
Remarks
According to FC-BB-5, the upper limit of the FKA
advertisement interval value is 90 seconds. In this
scenario, an FCF switch or NPV switch operating in
standalone mode or in IRF mode but without subordinate
switches will experience FCoE traffic disruption during
an ISSU reboot for the following reasons:
The ISSU reboot takes more than 225 (2.5*90)
seconds.
The peer deletes the virtual link for failing to receive
unsolicited Discovery Advertisements within 225
seconds.
You must also adjust the FKA advertisement interval
value on the upstream FCF switch to ensure service
continuity in the following cases:
Active/standby switchover on an NPV switch .
ISSU reboot on an IRF member NPV switch with
subordinate switches.
You must do that for the following reasons:
The FKA advertisement interval value configured on
the NPV switch affects only its VFC interfaces in F
mode and connected ENodes.
Its VFC interfaces in NP mode use the FKA
advertisement interval value learned from the
upstream FCF switch.
For more information about ISSU, see Fundamentals
Configuration Guide.
During an ISSU reboot on a switch operating in
standalone mode or in IRF mode but without subordinate
switches, the switch cannot send unsolicited Discovery
Advertisements or keepalive frames.