[SwitchA-Vfc4] fc mode e
# Bind VFC 4 to interface Ten-GigabitEthernet 1/0/4.
[SwitchA-Vfc4] bind interface ten-gigabitethernet 1/0/4
# Assign VFC 4 to VSANs 10 and 20 as a trunk port.
[SwitchA-Vfc4] port trunk vsan 10 20
[SwitchA-Vfc4] quit
# Configure Ten-GigabitEthernet 1/0/4 as a trunk port, and assign the port to VLANs 10 and 20.
[SwitchA] interface ten-gigabitethernet 1/0/4
[SwitchA-Ten-GigabitEthernet1/0/4] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/4] port trunk permit vlan 10 20
[SwitchA-Ten-GigabitEthernet1/0/4] quit
# Enable FCoE for VLAN 10, and map VLAN 10 to VSAN 10.
[SwitchA] vlan 10
[SwitchA-vlan10] fcoe enable vsan 10
[SwitchA-vlan10] quit
# Enable FCoE for VLAN 20, and map VLAN 20 to VSAN 20.
[SwitchA] vlan 20
[SwitchA-vlan20] fcoe enable vsan 20
[SwitchA-vlan20] quit
Configure Switch B in the same way Switch A is configured.
2.
Verifying the configuration
1.
Verify the configuration on Switch A by displaying member interfaces of each VSAN.
[SwitchA] display vsan port-member
VSAN 1:
Access Ports:
Trunk Ports:
VSAN 10:
Access Ports:
Trunk Ports:
Vfc1
Vfc4
VSAN 20:
Access Ports:
Trunk Ports:
Vfc2
Vfc4
2.
Verify the configuration on Switch B in the same way as you verify the configuration on Switch A.