Elan S12 And S8; Elan S6 - Elan VIA!4.0-EM Installation Manual

4"/7"/10" color lcd touch panels
Table of Contents

Advertisement

VIA!4.0-EM/VIA!7.0-EM/VIA!10.0-EM

ELAN S12 and S8

Use a local PVIA1 to connect a VIA! Touch Panel to a PS12 or SPP Precision
Panel located more than 200 feet away.

ELAN S6

Use a local PVIA1 to connect a VIA! to an ELAN S6 located more than 200
feet away.
Note: The SPP System Precision Panel may also be used for this
application. Connections are identical to those shown in Figure
3.23.
S6
Page 34
ELAN
C45P
>200 Feet
SPP or PS12
VIA Connector
SN
Blue
IR
White/Blue
485-
Orange
485+
White/Orange
GND
Green
+16V
White/Green
GND
Brown
+16V
White/Brown
Figure 3.23: S12/S8 Connections > 200'
ELAN
C45P
>200 Feet
ELAN
C45P
Figure 3.24: S6 Connections > 200'
© ELAN Home Systems 2007 • All rights reserved.
E L A N H O M E S Y S T E M S
<110 Feet
White/Brown
Brown
White/Green
Green
White/Orange
Orange
White/Blue
Blue
N/C
N/C
N/C
N/C
N/C
<110 Feet
White/Brown
Brown
White/Green
Green
White/Orange
Orange
White/Blue
Blue
N/C
White/Brown
N/C
Brown
White/Green
N/C
Green
White/Orange
Orange
N/C
White/Blue
Blue
N/C
PVIA1 Rear
+16V
GND
+16V
GND
V485+
PWR1
V485-
IR
ST/SNS
Z485+
Z485-
Use BOTH Twisted
Pairs For Power
(GR,GR/WH & BR, BR/WH)
PVIA1 Rear
+16V
GND
+16V
GND
V485+
PWR1
V485-
IR
ST/SNS
Z485+
Z485-
Use BOTH Twisted
Pairs For Power
(GR,GR/WH & BR, BR/WH)