RS-232 Controlled Devices (Regardless of System Type)

By adding an SC-4 Serial Controller or SS1 System Station to any system
using VIA! Touch Panels, powerful RS-232 control becomes possible for
a wide assortment of devices such as security systems, lighting systems,
HVAC, spa control, A/V gear, etc. Use the appropriate PVIA Wall Plate or
Precision Panel for the number of VIA! Touch Panels in the system and the
system type. When installing an SC-4/SS1 in an S12 or S8 system, a PVIA
Wall Plate is not needed; the SPP or PS12 Precision Panel has all necessary
provisions.
Stand-Alone, Z•Systems
S6, S8, or S12 Systems
© ELAN Home Systems 2007 • All rights reserved.
PVIA1
PWR9
TO SC-4
VIDEO IN
VIA!SC4
COM 1
COM 2
NETWORK
INTERFACE
COM 3
COM 4
SPP
Figure 2.7: RS-232 Controlled Devices
VIA!4.0-EM/VIA!7.0-EM/VIA!10.0-EM
PVIA4
IR
OUT
PWR1
1
2
IR
3
OUT
4
or
1
2
PVIA-4
9 VDC
SENSE
ALL
INPUTS
SYS
SENSE
+16VDC
POWER
3
4
TO SC-4
VIDEO
IN
1 1
3 3
2 2
4 4
SS1
or
DC RELAY PWR
RELAY 1
HOST RS-232
COM 1
ELAN
POWER
RS-232
16VDC
OUT
ELAN RS-232
COM 3
HOST
ELAN
RS-232
Devices
VIA!NET
EXT IR
TO SENSE INPUTS
SS/SC4
1
2
3
USE STEREO 3.5mm PLUGS ONLY
4
5
6
ZONE
ZONE
1
5
TRIGGERS
1
2
3
4
ZONE
ZONE
2
5
6
7
8
6
POWER
ZONE
ZONE
SS1
3
7
+
- -
ZONE
ZONE
16VDC / 10A
4
8
16VDC / 4A
DC RELAY PWR
16VDC/1.5A
HOST RS-232
ELAN RS-232
HOST
ELAN
PVIA10
or
RELAY 2
RELAY 3
RELAY 4
RELAY 5
RELAY 6
RELAY 7
COM 2
IR-LINK
SENSE INPUTS
IR OUTPUTS
1
2
3
ALL IR OUTPUT
1
2
3
COM1
ETHERNET
COM 4
4
5
6
7
8
9
COM2
COM3
LINK
COM4
RX/TX
EXT IR INPUT
VIA!SC4
COM 1
COM 2
NETWORK
INTERFACE
COM 3
COM 4
or
RELAY 1
RELAY 2
RELAY 3
RELAY 4
RELAY 5
RELAY 6
COM 1
COM 2
IR-LINK
SENSE INPUTS
2
1
3
ALL IR OUTPUT
COM1
ETHERNET
COM 3
COM 4
4
5
6
COM2
COM3
LINK
COM4
RX/TX
EXT IR INPUT
RS-232
Devices
LEXINGTON, KY • MADE IN CHINA
MODEL: VIA2SS1
RELAY 8
WARNING: DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICE TO ELAN-APPROVED
SERVICE TECHNICIAN.
4
5
6
VIA!2SS1
POWER
12VDC
0.5 AMPS
10
11
12
VIA-NET
-
+
IR
PWR
ELAN
POWER
RS-232
16VDC
OUT
LEXINGTON, KY • MADE IN CHINA
MODEL: VIA2SS1
RELAY 7
RELAY 8
WARNING: DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICE TO ELAN-APPROVED
SERVICE TECHNICIAN.
IR OUTPUTS
4
5
1
2
3
6
VIA!2SS1
POWER
12VDC
0.5 AMPS
7
8
9
10
11
12
VIA-NET
-
+
IR
PWR
Page 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Via!7.0-emVia!10.0-em

Table of Contents