Elan Z•System - Elan VIA!4.0-EM Installation Manual

4"/7"/10" color lcd touch panels
Table of Contents

Advertisement

VIA!4.0-EM/VIA!7.0-EM/VIA!10.0-EM
ELAN Z•System
Use a PVIA Wall Plate and a PZ6 Precision Panel for when installing VIA!s in
a Z•System. Connect IR, RS485+/-, GND, and +16VDC from the PVIA Wall
Plate to the VIA! Touch Panel as shown. Connect IR, RS485+/-, and GND
between the PVIA Wall Plate and the PZ6, as shown. Multiple VIA!s will con-
nect in the same way. Please consult the Z•630 Installation Manual for addi-
tional details.
Zone 1 Shown
PZ6 Rear
Use BOTH Twisted
Pairs For Power
(GR,GR/WH & BR, BR/WH)
Page 32
ELAN
C45P
GND
P & DB
Figure 3.21: Z•System Connections
© ELAN Home Systems 2007 • All rights reserved.
E L A N H O M E S Y S T E M S
White/Brown
Brown
White/Green
Green
White/Orange
Orange
White/Blue
Blue
N/C
Standard ELAN RJ-45 Pin-Out
TAB
PVIA1 Rear
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
PIN # COLOR CODE
1
BLUE
2
WHITE/BLUE
3
ORANGE
4
WHITE/ORANGE
5
GREEN
6
WHITE/GREEN
7
BROWN
8
WHITE/BROWN
CABLE