Motor Start Recorder - Eaton EMR-5000 Installation, Operation And Maintenance Manual

Motor relay
Table of Contents

Advertisement

Motor Start Recorder

Available Elements:
Start rec
The Motor Start Recorder is accessed using PowerPort-E or via the front panel interface of the relay. This feature
provides information recorded at the time of each start of the motor such as:
Date of the motor start event;
Record number;
And the summary data:
Maximum RMS phase current of each phase at the time of start;
Current unbalance;
TSTI and TSTR values;
Thermal capacity used ( I2T Used); and
Number of successful starts.
Managing Start Records
The start recorder data can be downloaded by means of PowerPort-E from the device when the User has selected the
"Start Rec" feature. To navigate to this feature, the User must go to the [Operation / Recorders] menu. Here the User
will find the »Start Rec« menu item. By selecting »Start Rec«, the Start Recorder Window will appear.
To access data that has been stored in the device using PowerPort E , the User must select the "Receive Start
Recorder" button in the upper left hand corner of the "Start Rec" window. When clicked, the PowerPort-E
software will retrieve the highlighted record from the device.
A summary of the Start Recorder data can be retrieved by selecting the "Receive Summary Data" button in the
upper left hand corner of the "Start Rec" window.
A list of all currently available Start Records is viewable by selecting the "Refresh Start Recorder" button on the
start recorder.
It is possible to delete individual records that are stored on the protective device. First, select "Receive Start
Recorder", and then select the record to be deleted by clicking on the record number, followed by the selection
of the "Delete Start Record" button in the upper left hand corner of the "Start Rec" window.
EMR-5000
www.eaton.com
IM02602012E
283

Advertisement

Table of Contents
loading

Table of Contents