4.1.5

Electrical Tests

Specifications
Standards:
Insulation test
Standards:
High voltage test (routine test)
all circuits except power supply, binary inputs, and com-
munication / time sync. interfaces
High voltage test (routine test)
auxiliary voltage, binary inputs and outputs
High voltage test (routine test)
only isolated communication and time synchronisation
interfaces
Impulse voltage test (type test)
all circuits except communication and time synchronisa-
tion interfaces, Class III
EMC Tests for Immunity (type tests)
Standards:
High frequency test IEC 60255-22-1, Class III and VDE
0435 Section 303, Class III
Electrostatic discharge
IEC 60255-22-2, Class IV
and IEC 61000-4-2, Class IV
Irradiation with HF field, frequency sweep
IEC 60255-22-3, Class III
IEC 61000-4-3, Class III
IEEE Std C37.90.2-2004
Irradiation with HF field, single frequencies
IEC 60255-22-3, IEC 61000-4-3, Class III,
IEEE Std C37.90.2
–amplitude-modulated –pulse-modulated
Fast transient disturbances /
Burst IEC 60255-22-4 and IEC 61000-4-4, Class IV
High energy surge voltages (SURGE),
IEC 61000-4-5 installation Class 3
- Auxiliary voltage
- Analog measuring inputs, binary inputs, relay outputs
7SD610 Manual
C53000-G1176-C145-4
IEC 60255 (product standards)
IEEE Std C37.90.0/.1/.2
UL 508
VDE 0435
For more standards see also individual functions
IEC 60255-5 and IEC 60870-2-1
2.5 kV (rms), 50 Hz
3.5 kV–
500 V (rms), 50 Hz
5 kV (peak), 1.2/50 µs, 0.5 Ws, 3 positive and 3 negative im-
pulses at intervals of 5 s
IEC 60255-6 and -22, (product standards)
EN 61000-6-2 (generic standard)
VDE 0435 part 301DIN VDE 0435-110
2,5 kV (peak); 1 MHz; τ = 15 µs; 400 surges per s; test dura-
= 200 Ω
tion 2 s; R
i
8 kV contact discharge; 15 kV air discharge, both polarities;
= 330 Ω
150 pF; R
i
10 V/m and 20 V/m; 80 MHz to 1000 MHz; 80 % AM; 1 kHz
10 V/m; 800 MHz to 960 MHz; 80 % AM; 1 kHz
10 V/m; 1,4 GHz to 2,7 GHz; 80 % AM; 1 kHz
20 V/m; 80; 160; 450; 900 MHz; 80 % AM; 1kHz; duty cycle
> 10 s
35 V/m; 900 MHz; 50 % PM, repetition frequency 200 Hz
4 kV; 5/50 ns; 5 kHz; burst length = 15 ms; repetition rate
= 50 Ω; test duration 1 min
300 ms; both polarities: R
i
Impuls: 1,2/50 µs
Common mode: 2 kV; 12 Ω; 9 µF
Diff. mode: 1 kV; 2 Ω; 18 µF
Common mode: 2 kV; 42 Ω; 0,5 µF
Diff. mode: 1 kV; 42 Ω; 0,5 µF