Mechanical Tests

Vibration (Sinusoidal)
IEC 60255-21-1 Class I
Type
Level
Vibration response
0.5 gn
Vibration endurance
1.0 gn
Shock and Bump
IEC 60255-21-2 Class I
Type
Level
Shock response
5 gn, 11 ms
Shock withstand
15 gn, 11 ms
Bump test
10 gn, 16 ms
Seismic
IEC 60255-21-3 Class I
Type
Level
Seismic response
1 gn
Mechanical Classification
Durability

Electrical Tests

Insulation
IEC 60255-5
Type
Between any terminal
and earth
Between independent
circuits
Across normally open
contacts
High Frequency Disturbance
IEC 60255-22-1 Class III
Type
Level
Common
2.5 kV
(longitudinal)
Series (transverse)
1.0 kV
mode
Electrostatic Discharge
IEC 60255-22-2 Class IV
Type
Level
Contact discharge
8.0 kV
Siemens Protection Devices Limited
Variation
≤ 5 %
≤ 5 %
Variation
≤ 5 %
≤ 5 %
≤ 5 %
Variation
≤ 5 %
>10
6
operations
Level
2.0 kV AC RMS for 1 min
2.0 kV AC RMS for 1 min
1.0 kV AC RMS for 1 min
Variation
≤ 5%
≤ 5%
Variation
≤ 5%
Fast Transients
IEC 60255-22-4 Class IV
Type
Level
5/50 ns 2.5 kHz
4 kV
repetitive
Surge Immunity
IEC 60255-22-5
Type
Level
Between all
4.0 kV
terminals and earth
Between any two
2.0 kV
independent circuits
Conducted Radio Frequency Interference
IEC 60255-22-6
Type
Level
0.15 to 80 MHz
10 V
Radiated Radio Frequency
IEC 60255-25
Type
30 to 230 MHz
230 to 10000 MHz
Conducted Radio Frequency
Type
Limits
Quasi-peak
0.15 to 0.5 MHz
79 dB(µV)
0.5 to 30 MHz
73 dB(µV)
Radiated Immunity
IEC 60255-22-3 Class III
Type
Level
80 MHz to 1000 MHz
10 V/m
Magnetic Field with Power Frequency
IEC 61000-4-8, Class V
Type
100 A/m (0.126 mT) continuous
1000 A/m (1.26 mT) for 3s
Variation
≤ 5%
Variation
≤ 10% or 1 mA
Variation
≤ 5%
Limits at 10m, Quasi-peak
40 dB(µV/m)
47 dB(µV/m)
Average
66 dB(µV)
60 dB(µV)
Variation
≤ 5%
Level
50 Hz
7