2. Zone Configuration
2. Zone Configuration
2 . 1 S t a n d a r d (continued)
2 . 1 S t a n d a r d
2.1.8.3 Bell 2
Z## BELL 2
YES 0=NO 1=YES
Enable this option for the SMDC to activate a steady output from Bell 2
when this zone initiates an alarm condition. (see 1.2 Cutoff Times / wiring diagram).
2.1.8.4 Bell 2 Pulse
Z## BELL 2 PULSE
NO 0=NO 1=YES
Enable this option for the SMDC will activate a pulsed output from Bell 2
when this zone initiates an alarm condition. (see 1.2 Cutoff Times / wiring diagram).
N o t e : 2.1.8.3 Bell 2 output must be programmed as YES for this Pulse Bell option to function.
N o t e
2.1.8.5 Relay 1
Z## RELAY 1
NO 0=NO 1=YES
Enable this option for the SMDC to activate Relay 1 when this zone initiates an alarm
condition. (see 1.2 Cutoff Times / wiring diagram).
2.1.8.6 Relay 2
Z## RELAY 2
NO 0=NO 1=YES
Enable this option for the SMDC to activate Relay 2 when this zone initiates an alarm
condition. (see 1.2 Cutoff Times / wiring diagram).
2.1.8.7 PGM 1
Z## PGM 1
NO 0=NO 1=YES
Enable this option for the SMDC to activate PGM 1 when this zone initiates an alarm
condition. (see 1.2 Cutoff Times / wiring diagram).
2.1.8.8 PGM 2
Z## PGM 2
NO 0=NO 1=YES
Enable this option for the SMDC to activate PGM 2 when this zone initiates an alarm
condition. (see 1.2 Cutoff Times / wiring diagram).
2.1.8.9 PGM 3
Z## PGM 3
NO 0=NO 1=YES
Enable this option for the SMDC to activate PGM 3 when this zone initiates an alarm
condition. (see 1.2 Cutoff Times / wiring diagram).
2.1.9 Alarm Verify
Z## ALARM VERIFY
NO 0=NO 1=YES
Enabling this option will help in the reduction of false alarms in that the SMDC will
recognize an alarm state on this zone and will then start a timer "window" of 60 seconds
and must recognize subsequent alarm activation from the same circuit within the
"window" before the panel will initiate an actual alarm condition.
N o t e : This feature can't be used for any UL Listed application.
N o t e
Optex Inc. - 1845 W 205th St. - Torrance, Ca. 90501 - 800-966-7839
Selections: Yes / No
Default: Yes
Selections: Yes / No
Default: No
Selections: Yes / No
Default: No
Selections: Yes / No
Default: No
Selections: Yes / No
Default: No
Selections: Yes / No
Default: No
Selections: Yes / No
Default: No
Selections: Yes / No
Default: No
SMDC-16 Program Manual
2. Zone Configuration
(Set Zone #)
1. Zone Config.
1. Zone Type
2. Loop Type
3. Report Codes
1. Alarm
2. Trouble
3. Bypass
4. Cancel
5. Restore
4. Zone Name
5. Loop Response
6. Entry Delay
7. Zone Features
1. Silent Day/
Audible Night
2. Telephone
3. Radio
4. Bypass Allowed
5. Shunt Allowed
6. Display Armed
7. Walk Test
8. Monitor Mode
9. Auto Walk at Arm
8. Zone Outputs
1. Bell 1
2. Bell 1 Pulse
3. Bell 2
4. Bell 2 Pulse
5. Relay 1
6. Relay 2
7. PGM 1
8. PGM 2
9. PGM 3
9. Alarm Verify
2. Templates
(Set Zone Type)
1. Loop Response
2. Zone Features
1. Silent Day/
Audible Night
2. Telephone
3. Radio
4. Bypass Allowed
5. Shunt Allowed
6. Display Armed
7. Walk Test
8. Monitor Mode
9. Auto Walk at Arm
3. Zone Outputs
1. Bell 1
2. Bell 1 Pulse
3. Bell 2
4. Bell 2 Pulse
5. Relay 1
6. Relay 2
7. PGM 1
8. PGM 2
9. PGM 3
3. Cross Zone Pairs
1. Cross Zone Pair 1
1. Zone A
2. Zone B
2. Cross Zone Pair 2
1. Zone A
2. Zone B
3. Cross Zone Timer
4. # of Shunt Alarms
5. Shunt Period
6. # of Expander Bds.
3440-0252 A4