7.7 Parameterization
In SERVICE mode all menu items marked with */SP can be configured.
In SPECIALIST mode all menu items marked with */SP and **/SE can be configured. All other items can
only be displayed (D)
7.7.1
Submenu level 1 → PARAMETER MENU
Display indication
42/14-39 EN
Sensyflow iG, Version 1.00
Submenu level 1
TAG NO.
INSTALL. DATE
LANGUAGE
DP SLAVE ADDRESS
PROFIBUS BAUD
PROFIBUS STATUS
CHARACTERISTIC CURVE
DEFAULT DISPLAY
CONTRAST
LOAD FACTORY CONF.
LOAD USER CONF.
SAVE USER CONF.
IRDA INTERFACE
HARDWARE RESET
HW SW REV
MANUFACTURER ID
DEVICE ID
SERIAL NO.
ORDER NO.
END PARAMETER MENU
Operation, configuration and communication
Explanation
SP
19 digit alpha-numeric input possibility for the measuring point
designation (TAG no.)
SP
Input possibility for the installation/commissioning date
SP
Language selection German, English, French, and a fourth lan-
guage, currently Portuguese
SP
Input of PROFIBUS address in the range 0...126 (do not use
address 0 and 126!)
D
Display of current PROFIBUS data transfer rate
D
Display of the current PROFIBUS status
SP
Select from a maximum of four factory-set characteristics.
(option)
SP
Select the display screen that is shown at device start-up
SP
Display contrast setting, dependant on ambient temperature,
adjustable by repeatedly pressing the ENTER button
SP
The factory configuration overwrites the currently set configu-
ration.
SP
The stored user configuration overwrites the currently set con-
figuration.
SP
Stores the current configuration
SP
Not available at present
SP
Simulates the interruption of power. The device is restarted and
switches to normal operation, if no error is present. The current
configuration is saved and reloaded at start-up. On the display
the screen selected in DEFAULT DISPLAY is shown.
D
Indication of hardware and software revision numbers
D
Indication of manufacturer identification number
D
Indication of device identification number
D
Indication of the device serial number (manufacturing number)
D
Indication of manufacturer order number