Schwinn MPower Echelon2 Service Manual page 64

Console
Hide thumbs Also See for MPower Echelon2:
Table of Contents

Advertisement

8.
Once the calibration passes, go to CALIBRATE
CURRENT ANGLE and verify the angle is 0.0 (+/-
0.1 degrees)
Occasionally, the calibration process does not
correctly set the angle on the first try. If the angle
reads anything other than 0.0 (+/- 0.1 degrees),
perform the calibration again until the CURRENT
ANGLE reads 0.0 (+/- 0.1 degrees).
Note: The sensor measures in degrees, so 0.0 –
0.1 = 359.9.
9.
At this point calibration is done. Exit the service
menu and remove the tool from the flywheel
(keep for future use, the tool can be stored under
the cosmetic bracket cover for safe keeping)
Checking current angle:
1.
With the console powered on, hold the STAGE and AVG/MAX buttons at the same time for about 5-10 seconds
to enter the service menu.
2.
Once in the service menu, use the AVG/MAX button to scroll until "CALIBRATE" is displayed at the top of the
screen, then press the LIGHT button to enter the calibration sub-menu.
3.
Use the AVG/MAX button to scroll until "CURRENT ANGLE" is displayed. The number on that screen is the current
angle of the power sensor relative to the zero point.
Page 64