Schwinn MPower Echelon2 Service Manual page 34

Console
Hide thumbs Also See for MPower Echelon2:
Table of Contents

Advertisement

Zeropoint Calibration Procedure
The Zeropoint Calibration Procedure ensures that the console will display the rider status. It sets the zeropoint for the
power sensor and allows the console to use a formula, with the RPMs and the angle of the brake as variables, to provide
calories, power, and RPMs.
1.
Power on the console
2.
Enter the service menu by holding down the STAGE and AVG/
MAX buttons together for about 4-6 seconds.
3.
Once in the service menu, use the AVG/MAX button to scroll
to the CALBRATE menu. Press and release the LIGHT button to
enter the menu.
4.
Scroll to CALIBRATE ZEROPOINT option and press the LIGHT
button.
Page 34