3.8 Variations in Operating Range

Influential
Quantity
Battery
Voltage
Temperature
-10° to +55°C
Humidity
10 to 80% RH
Frequency
15 to 500Hz
AC voltage
superimposed on
0% to 20% Vn
test voltage
*The terms DAR, PI, DD and the capacity and current leak measurements are included in the quantity "MΩ".
18
Range of
Influence
Influenced*
9V to 12V
MΩ (10kΩ to 40GΩ)
MΩ (40GΩ to 10TΩ)
Quantity
V
MΩ
V
0.15% R/10°C
MΩ
V
V
MΩ
0.1% R / % Vn
Influence
Typical
<1ct
<1ct
0.3% R ± 1ct
0.20% R
1% R ± 1ct
0.2% R
1% R ± 2cts
0.2% R
1% R ± 5cts
3% R
15% R ± 5cts
0.3% R
0.5% R ± 1ct
0.1% R / % Vn ± 5cts
Megohmmeter Model 5070
Max
2cts
3cts