Core Dimensions And Mounting; Airflow; Acoustic Noise; Support - Calrec Artemis Installation And Technical Manual

Digital broadcast production console
Hide thumbs Also See for Artemis:
Table of Contents

Advertisement

CORE DIMENSIONS AND MOUNTING

The Artemis Shine/Beam processing
core is an 8U 19' rack mount
enclosure designed for installation in
standard 19' equipment bays.

Airflow

The core is cooled by fan assisted
convection. Air is drawn in from the front
into the cable-tray and up through the
base of the card frame. Fans mounted
in the top of the core pull air through the
card frame which then exits through vents
across the top of the rear of the core. All
fans are speed monitored and System
Status error message are generated
for any failures. To ensure air can flow
through the card frame freely, the air
vents at the rear of the core should be
left clear and unobstructed. Also, the
cable-tray should not be overfilled, leaving
space at the base of the card-frame by
using the cable-tidy clips in the cable tray.
No clearance is required above or below
the core for cooling.
AcousticNoise
A fully populated core has been measured
to produce <40dB acoustic noise
(A-weighted at 1 metre from front).

Support

The weight at the rear of the core should
be adequately supported to prevent
stress on the front racking angles. This is
particularly important when the units are
mounted in mobile installations. Calrec
will not accept liability for damage caused
by insufficient support.

Connections

All connections, including power are made
to the front of the core which is recessed
from the racking angles to allow cable
clearance within the bay.
A cable tray in the base of the core allows
for cables to be routed from the rear of
the bay to the front of the core. Cable tidy
28 ARTEMIS
Digital Broadcast Production Console
SIDE PROFILE VIEW - DIMENSIONS & AIR FLOW
8 U
356mm
[14.02"]
80mm
[3.15"]
Air enters through the
front of the cable-tray
CORE SPECIFICATIONS
Height
Depth
Width
Weight
Heat Dissipation
clips in the cable tray keep cables at the
base ensuring airflow into the cardframe is
not restricted.
When routing cables through the
cable tray and up to front panel
connectors, observe the minimum
bend radii recommended by the cable
manufacturers. This is especially
important for fibres and high speed data
conductors.
498mm [19.61"]
Cable path
ED5708 Core
8U (356mm)
498mm
19'
17kg (max)
300W (max)
Take care also to 'dress' cables neatly so
that they cause minimal restriction to the
air flow.
Please refer to the Hydra2 installation
manual for detail regarding specific router
connections.
Processing Core – Beam / Shine
Air exits
through
rear vent
27mm
[1.06"]
Cable entry