Page 1
BRIO 36 INSTALLATION MANUAL Audio Production System with Optional Networking calrec.com Putting Sound in the Picture...
Page 2
England UK equipment without notice. Any changes we make Apollo, Artemis, Summa, Brio 36, Hydra Audio HX7 8EZ will be reflected in subsequent issues of this Networking and Bluefin High Density Signal document.
Calrec product Ireland,shippingviathedistributorsaves AllunitsproducedbyCalrecaregiven please contact your regional Calrec customersfromdealingwithexportation aserialnumberandarebookedinto distributor. Customers within the paperwork.Ifthereisaneedtosend acentralrecordsystematthetime UK or Ireland should contact Calrec directtoCalrec,contactusbeforehandto ofmanufacture.Theserecordsare directly. logtheincomingrepairandforassistance updatedwheneverapieceofhardwareis withexportationdocuments. dispatchedtoorreceivedfromacustomer. For a complete list of worldwide distributors by region, go to www.
PACKAGE CONTENTS There are a number of options when ordering Brio 36 systems: connectivity type and I/O options. Everysystemincludesacontrolsurfacewhichcontainstheprocessingcore.Smallformatpluggabletransceivers(SFPs)arerequired forHydra2I/OboxconnectionswiththeoptionalHydra2moduleandcanbeprovidedbyCalrec.I/Opackagesareoptional. ThefollowingtableshowsallBrio36options: Surface and Core Packs Brio36issuppliedwith36physicalfaders,arrangedas3setsof12faderpanelsandaTFTscreen withitsassociatedcontrols. Eachfaderhasadedicatedfadermeterdisplay,2userdefinablelocalSwitchesS1andS2andauser rotarycontrolcellabove,aswellastheusualAFL/PFLandAccessswitches.Brio36issuppliedwith Brio 36 Surface On/CutbuttoncapsfittedforeachfaderandasoftwareoptiondeterminesifthisactsasaCUTor ONswitch.ThetoprighthandareacontainstheAccessdisplayareacompletewithtouchscreenTFT, 8contextbasedrotarycontrols,12GlobaluserswitchesG1toG12,A/Blayerselection,LinkSwitch, MonitorControls,PFLlevel,ResetswitchandaUSBportusedfordatatransfers. InthefrontoftheconsoleisprovidedafurtherUSBconnectoranda1/4”stereoheadphonesocket. Power,Router,ControlProcessor,andDSPareallselfcontainedwithintheunitwhichhas2xIEC connectorstoprovidePSUredundancy.Thecoreoperatesat44. 1 ,48,88.2&96kHzandsupports: 64legsasmono,stereoand5.
Page 10
10 BRIO 36 Audio Production System with Optional Networking...
REAR CONNECTIONS The BRIO 36 surface is designed to Theclipsmaynotprovideadequate equipmentforEmber+,SWP-08control be a self-contained compact mixing retentionontheirownforsomepre- orotherOEMinterfaces.Alternatively console however there are a number fabricatedIECconnectortypes.Ifthere theycanconnecttoCalrecH20orCalrec of external connections that are Assistinterfaces. isconcernovertheconnectorsworking made to interface to other equipment looseduringtransit,werecommendthat such as I/O, Networks and OEM IECsocketswithbuiltinlatchingareused.
I/O list. Note, Some customers may find 3. OpentheCSVfileinaneditor,suchas that their I/O boxes have been pre- MicrosoftExcel. Itisimportantthatcarefulconsiderationis configured with unique HIDs at the 4. Foreachentry,updatetheHIDtoyour Calrec factory, prior to dispatch. giventoHIDsettingspriortoconnecting newvalue. anyI/Oboxestothenetwork,especiallyif 5. ImporttheCSVfilebackintoH2Ofor futurenetworkingofstandalonesystems ChanginganI/OBox’sHID thecorrectI/Obox.
The remaining switches are double the value of their less significant neighbour, making the 8th/most significant bit equate to a decimal value of 128. AllfixedformatI/OboxIDswitchesare orientatedthesameway,thoughsome boxes,suchasMADIunits,useadifferent styleswitchwithmorepronounced labelling.Ignoreanylabelsontheswitch itselfandalwaysrefertotheCalrec labellingonthesurroundingpanelwhich willshowthemostsignificantbitswitchon theleftandthebinary1positionasup. Address2 SomeI/Oboxes,suchasMADIunits, arefittedwith2banksofDIPswitches— Address1andAddress2—toprovidea 16bitIDandthereforeagreaterrange ofvalues.PleasenotethatonlyID valuesbetween0and255arecurrently supported.AnyDIPswitcheslabelled...
CONNECTING BRIO 36 TO A ROUTER CORE In order to connect to other consoles Foraredundantsystem,twoconnections withtheBrio36primaryconnectedto that you wish to use with a Brio 36 arerequired,primaryandsecondary. theprimaryroutercardandtheBrio36 system it should be connected to InthediagrambelowtheBrio36is secondaryconnectedtothesecondary the core router card(s) using fibre connectedtoa4UArtemisLight/ routercard.Notethatnetworking...
HARDWARE POWER CONNECTIONS Brio 36 and Hydra2 hardware requires mains power via standard IEC connections. WhileCalrechardwarecanberunoffonepowerconnection,itisadvised,forredundancy,thatyouconnectaseparatepowersource totheprimaryandsecondarypowerinlets.Inthefollowingdiagramstheprimarypowerconnectionsareindicatedbyasolidarrowand thesecondaryconnectionsbyadashedarrow. POWER CONNECTIONS TO THE BRIO 36 SURFACE POWER CONNECTIONS TO THE 2015 CORE POWER CONNECTIONS TO A MODULAR I/O BOX POWER CONNECTIONS TO A FIXED FORMAT I/O BOX...
Shows and memories and log files are SETTING THE DATE AND TIME time-stamped, making them easier to identify. When you first start up your Brio 36 system it is important to set the current date and time. Todothis: TapSYSTEMSETTINGSinthetop righthandcornerofthetouchdisplay.
CONNECTING A LAPTOP TO BRIO 36 A laptop can be used on Brio 36 to CONNECTING A LAPTOP access H2O for I/O port management and labelling, and to carry out software updates. Thelaptopwillneedtohaveatleastone ethernetport(orUSBLANconnector) whichshouldbeconnectedtothe ‘Ethernet1orEthernet2connectionwhich islocatedontherearoftheBrio36unit. Thelaptopwillneedtobeconfiguredtouse astaticIPaddressforitsLANconnection. Theaddresschosenshouldbecompatible withtheaddressoftheportontheconsole itisbeingconnectedto.
CONFIGURING LAN PORTS The Brio 36 control processor has CONTROL PROCESSOR LAN PORTS two ports labelled LAN (or Ethernet) 1 and 2, on the rear of the unit. These ports can be used to connect the Brio 36 system to third party controllers for...
SURFACE MEASUREMENTS Thefollowingdiagramsshowthesurfacemeasurementsallinmillimeters(mm). TOP VIEW 24 BRIO 36 Control Surface Audio Production System with Optional Networking...
Page 25
FRONT VIEW SIDE VIEW CALREC Putting Sound in the Picture...
SURFACE LAYOUT The BRIO 36 surface is built as 2 panels top and bottom. It is made up from 3 x 12 fader sections, 2 across the bottom and one top left and one Access Panel placed top right which contains the Access display area complete with touchscreen TFT, 8 context based rotary controls, 12 Global user switches G1 to G12, A/B layer selection, Link Switch, Monitor Controls, PFL level, Reset switch and USB port used for data transfers.
AlthoughBrio36willrunwithonlyone card.Note,theTouchDisplayalsohasa with no loss of audio or operation. PSUpoweredon,itisrecommendedthat, backlightwhichispoweredviaaseparate toensurepowerredundancy,thesetwo 12VDCconnectionfromtheProcessing IECinletsshouldbesuppliedbyseparate DisconnectingthePSUs Enginecard. ACpowersupplies. Brio36doesnotcontainaseparate Mainspowerswitch.Tosafelydisconnect themainspowerbothIECconnectors needtoberemovedfromtherearofthe console,asshownbelow. BRIO 36 REAR VIEW SHOWING PSU MAINS CONNECTION AND RATINGS LABEL CALREC Putting Sound in the Picture...
Page 30
30 BRIO 36 Audio Production System with Optional Networking...
SYNCHRONISATION The Brio 36 has 6 BNC connections SYNC INPUTS Theconsolewillalwaysattempttoboot for external synchronisation:- tothehighestprioritysyncselected,and 2 x Wordclock inputs, 2 x AES inputs movedowntheprioritylistuntilitfindsa and 2 x Video inputs. If no external validsync. sync is connected and selected, the console will free-run on its own...
AUDIO I/O CONNECTIONS There are a number of ways to get OptionalHydra2AudioFormats configurationusingH20andresetting Audio in and out of a Brio 36 system. Hydra2I/Ounitscomeinavarietyof themasterrouterisrequiredtoaddthe There are built in Analogue and Digital formatsandconnectortypes,including replacementcardsinH2O. Inputs, 3 double width modular I/O MADIandSDIembedders/de-embedders,...
Page 34
FIXED FORMAT I/O REAR CONNECTIONS ConnectionfromPrimary Hydra2SFPonBrio36 ConnectionfromSecondary Hydra2SFPonBrio36 NoConnection MODULAR HYDRA2 I/O, CONTROLLER CARD FRONT INTERFACE ConnectfromPrimary Hydra2SFPonBrio36 ConnectfromSecondary Hydra2SFPonBrio36 34 BRIO 36 Connection Information Audio Production System with Optional Networking...
Page 35
FIXED FORMAT MADI HYDRA2 I/O, REAR INTERFACE ConnectionfromPrimaryHydra2SFPonBrio36 ConnectionfromSecondaryHydra2SFPonBrio36 PROCESSING 2015 CORE—HYDRA 2 ROUTER I/O PORTS FOR CONNECTING TO BRIO 36 FROM V2.0 ONWARDS PrimaryI/OPorts SecondaryI/OPorts CALREC Putting Sound in the Picture...
SMALL FORM-FACTOR PLUGGABLE (SFP) OVERVIEW MODULAR I/O BOX SFPS Connections between the Brio 36 SFPslotorientation control surface (which includes SFPmodulesplugintorearpanelslotson H2 I/F the processing core) and all Hydra2 Brio36&fixedformatI/Oboxes,andinto STATUS network connections, connections frontpanelslotsonrouterandmodular RESET between I/O boxes and routers and I/Ocontrollercards.Themodulescan...
ThefibreSFPsshownintheorientation dry,andanti-staticenvironment.Fibre diagramsandonthispageareofthistype SFPsshouldalwayshaveadustcover fittedintotheiropticaltransceiverend SFPS WITH HANDLES - LATCHED whennofibreisconnectedtothem. Calrec will not be liable for lost or missing SFP modules, or damage due to poor storage. SFPdesignvaries dependingonthemanufacturer,please ensurethatSFPsarecorrectlylatched • BothSFPsshownarelockedin inplaceafterfittingthem.Intheevent place-Latch/extractionhandles inouterposition(or‘down’position thataconnectionisnotautomatically forfibre).
SFPs must support LOS (Loss of cablesis90m/295ft.Thisisthe theycanincreasecross-talk,which Signal detection) - this is not standard absolutemaximumandneedstoinclude canimpactonperformance.Avoid for copper SFPs, but are commonly anypatchpointsandcablesthatmaybe neatbundlingofnetworkcablesover available, Calrec supplied Copper inthepath.Hydra2cablerunscanNOT anykindofdistance—themajorityof SFPs do support LOS. acableslengthisnormallyunseen, beextendedusingEthernetswitches, hubsorrepeaters.Ifarunbetween runningunderfloororthroughducting Calrecdonotsupplycoppercablesasit...
StandardCalrecfibreSFPs,both pathfromoneendtotheotherwithout multimodeandsinglemode,useduplex budgetoftheSFPtransceiversbeing used. DUPLEX LC FIBRES CORRECTLY TERMINATED A TO B & B TO A BI-DIRECTIONAL LC FIBRE CORRECTLY CONNECTED, TYPE A TO TYPE B 40 BRIO 36 Connection Information Audio Production System with Optional Networking...
Page 41
Connector Power Budget Fibre Type Max Distance 62.5/125µm 275m SX Multimode LCDuplex 7.5dB 50/125µm 550m LX Singlemode LCDuplex 8dB 8/125µm 10km LX Singlemode bi-dir LCSimplex 11.5dB 9/125µm 10km LH Singlemode LCDuplex 23dB 8/125µm 70km CALREC Putting Sound in the Picture...
GPIO CONNECTIONS GPIO cards provide logic inputs and INTERNAL FIXED - GPIO, 4 INPUTS + 4 ISOLATED/DRY CLOSURE OUTPUTS outputs, which can be assigned to various functions from the Brio 36 GPIconnectors1-4in&5-8in interface. Function GPIO allows console functions to trigger external devices e.g. fader...
Page 46
NormallyOpen Normally Made NormallyMade Common Common Ground Relay 8 Normally Open Relay 7 NormallyOpen Normally Made NormallyMade Ground Common Relay 8 NormallyOpen Ground NormallyMade Ground • Calrecconnectorismale,requiringfemaleterminatedcable • Calrecconnectorisfemale,requiringmaleterminatedcable 46 BRIO 36 Connection Information Audio Production System with Optional Networking...
Control over input portsandmustbeconfiguredfromthe to output cross-point routing can be Inmulti-console/multi-corenetworked LANConfigurationpageinSystem carried out from the Brio 36 touch systems,theconnectionshouldbemade Settings. screen interface, a standalone PC totheroutercardinthecoreconfigured running the Hydra2 Organiser (H2O), In addition to the IP address, the astheMaster.Slavedroutercoresdonot...
Inmulti-console/multi-corenetworked fromtheLANConfigurationpagein systems,theconnectionshouldbemade SystemSettings. EMBERcontrolhasbeenincorporated totheRoutercardinthecoreconfigured astheMaster.Slavedroutercoresdonot In addition to the IP address, the intoCalrec’sproductrangetoallow system will need to be configured to remotecontrolfunctionalityoverboth supportEMBERconnections.AnEMBER use TCP socket port 62000. mixingconsoles,andthewiderHydra2 connectionmadetothenetwork’sMaster network. RouterhasaccesstoalloftheI/Oand mixingconsolesontheHydra2network. Currently,Calrechavetested,andhave...
• Controloverandread-backofMain Settings. Calrecaudiomixingconsolesforlive,on- outputbuslevelsandPFLstatus. airapplications: • Read-backoftheconsole’sname/ID. In addition to the IP address, both the Calrec system and the 3rd party require configuring to use the same • RossOverdrive(AutomatedProduction CSCPV2.0providesthesame TCP socket port. The default TCP Controlsystem)&Rossvideo functionalityasV1.0withthefollowing socket port for CSCP is 49200.
Page 53
PORTS AVAILABLE FOR SW-P-08, EMBER & CSCP CONNECTIONS ON THE BRIO 36 REAR PANEL CALREC Putting Sound in the Picture...
Page 54
54 BRIO 36 Audio Production System with Optional Networking...
Theairintakeisonthesideventsoftheconsole. Cooling Atleast50mm(2’)clearanceshouldbemaintainedforthesevents. Ifthesidesareobstructed,thetrimswillpullairfrombelowandrear. Operating Ambient Air 0°C-40°C Temperature Note that Brio 36 is a self contained unit and the processing core is built into the console. BR-IO EXTERNAL I/O RACK BR-IO 240V Operation 115V Operation 100V Operation Supply Current 0.33A...
Page 62
RMSVAat115V.HeatoutputfiguresareavailableforalltypesofI/Obox. Heat Output and Efficiency ThelowpowerPSUefficiencyisagaindependantonsupplyvoltageandloading,generally >70%. AllfixedformatHydra2I/Ounitsof2Uorgreaterarecooledundercontrolwithfanassistance. Operationisnotdependantonthefan;itistheretoextendtheoperatinglifeoftheunit.There isan80mmlowpower,lowspeedandlownoisefanmountedtotherighthandsidepanelof eachunitventingair.Fanspeedismonitoredandsystemstatuswarningsaregeneratedif fanssloworfail.Airisdrawninthroughthelefthandsidepanel. Cooling 1UHydra2I/Oboxesdonotrequirefanassistancehavingsufficientsurfaceareatoradiate heatadequately. ThesidepanelsofallfixedformatHydra2I/Ounitsshouldbeunobstructedwithatleast 50mm(2’)clearancetoallowairflow.Noclearanceisrequiredaboveorbelowtheunit. I/Ounitsmaybemountedinanopenbayprovidingtheambientairtemperatureiswithinlimits (seebelow).Theunitsmayalsobehousedinanyairconditionedbay. Acoustic Noise <27dBSPL(A-weighted,1mfromfront). Operating Ambient Air 0°C-40°C Temperature Relative Humidity 5%-80%Non-Condensing 62 BRIO 36 Specifications Audio Production System with Optional Networking...
Page 63
Power TheoperatingACsupplyvoltageis100V-240V+/-10%. Thepeakinrushcurrentislimited(coldstart).Thisreducesthechanceofanuisancetripor fuseblowfrompowerup.TheRMSquiescentandpeakinrushcurrentfiguresaredependant uponthequantityandtypeofI/Ocardsfitted.PleaserefertotheHydra2installationmanual formoredetailsonmodularI/O. TheHeatoutputfrommodularHydra2I/Ounitsdependsuponthequantityandcardtypes Heat Output and Efficiency fitted,pleaserefertotheHydra2installationmanualformoredetailonmodularI/O. FansmountedtothePSUsatthebackofthecoredrawairthroughthePSUsandthecore itself.Airisdrawnupthroughthebaseofthecorewhichisrecessedtoallowairtoenter throughtheside,andfortheunitstobemountedwithnoclearanceaboveorbelow.The bottomofthesidesofthemodularI/Oboxshouldbeunobstructedwithatleast50mm(2’) Cooling clearancetoallowairflow. ModularI/Ounitsmaybemountedinanopenbayprovidingtheambientairtemperatureis withinlimits(seebelow).Theunitsmayalsobehousedinairconditionedbays. Acoustic Noise <27dBSPL(A-weighted,1mfromfront). Operating Ambient Air 0°C-35°C Temperature Relative Humidity 5%-80%Non-Condensing CALREC Putting Sound in the Picture...
Page 66
SRConI/P INPUTS 141dB 134dB to Digital Outputs with 0 dB gain +18dBu=0dBFS off 109dB 109dB to Analogue Outputs with 0 dB gain +24dBu=0dBFS off 115dB 115dB *Theanaloguetoanaloguedynamicrangeisachievedbecausethesystemcanacceptanaloguesignalsofupto+28dBufrominput tooutputat0dBgain.Obviously,ananalogueinputofupto+28dBumustbeattenuatedtooutputthisdigitally,butthisattenuation willmaintaintheDynamicRangeoftheinput,astheanalogueinputnoisewillbeattenuatedbythesameamountasthesignal,andthe analogueinputnoisewillstillbedominantabovethenoisefloorofthedigitalsystem. 66 BRIO 36 Specifications Audio Production System with Optional Networking...
Page 67
Built-In AES3 UNBALANCED DIGITAL systemsetfor SRConI/P SRConI/P OUTPUTS 141dB 134dB from Digital Inputs with 0 dB gain +18dBu=0dBFS N/A 108dB from Analogue Inputs with 0 dB gain +24dBu=0dBFS N/A 114dB *Theanaloguetoanaloguedynamicrangeisachievedbecausethesystemcanacceptanaloguesignalsofupto+28dBufrominput tooutputat0dBgain.Obviously,ananalogueinputofupto+28dBumustbeattenuatedtooutputthisdigitally,butthisattenuation willmaintaintheDynamicRangeoftheinput,astheanalogueinputnoisewillbeattenuatedbythesameamountasthesignal,andthe analogueinputnoisewillstillbedominantabovethenoisefloorofthedigitalsystem. CALREC Putting Sound in the Picture...
Page 70
INPUTS (MODULAR I/O ONLY) 138dB 130dB to Digital Outputs with 0 dB gain +18dBu=0dBFS off 111dB 111dB to Analogue Outputs with 0 dB gain +24dBu=0dBFS off 117dB 117dB *Theanaloguetoanaloguedynamicrangeisachievedbecausethesystemcanacceptanaloguesignalsofupto+28dBufrominput tooutputat0dBgain.Obviously,ananalogueinputofupto+28dBumustbeattenuatedtooutputthisdigitally,butthisattenuation willmaintaintheDynamicRangeoftheinput,astheanalogueinputnoisewillbeattenuatedbythesameamountasthesignal,andthe analogueinputnoisewillstillbedominantabovethenoisefloorofthedigitalsystem. 70 BRIO 36 Specifications Audio Production System with Optional Networking...
Page 71
HYDRA2 AES3 BALANCED DIGITAL systemsetfor SRConI/P SRConI/P OUTPUTS (MODULAR I/O ONLY) 138dB 130dB from Digital Inputs with 0 dB gain +18dBu=0dBFS N/A 110dB from Analogue Inputs with 0 dB gain +24dBu=0dBFS N/A 116dB *Theanaloguetoanaloguedynamicrangeisachievedbecausethesystemcanacceptanaloguesignalsofupto+28dBufrominput tooutputat0dBgain.Obviously,ananalogueinputofupto+28dBumustbeattenuatedtooutputthisdigitally,butthisattenuation willmaintaintheDynamicRangeoftheinput,astheanalogueinputnoisewillbeattenuatedbythesameamountasthesignal,andthe analogueinputnoisewillstillbedominantabovethenoisefloorofthedigitalsystem. CALREC Putting Sound in the Picture...
Need help?
Do you have a question about the BRIO 36 and is the answer not in the manual?
Questions and answers