POWER/ENVIRONMENTAL SPECIFICATION

CONTROL SURFACE
Power
Heat Output & Efficiency
Cooling
Operating Ambient Air
Temperature
Relative Humidity
CALREC
Putting Sound in the Picture
The console has two IEC AC power inlets feeding two sets of internal power distribution.
Although the console will operate with one inlet supply we recommend both inlets are powered.
This will ensure continued operation should a PSU or AC source fail. A third, ancillary IEC AC inlet
powers 3rd party single PSU items such as the PC monitor and surround meters.
The operating AC supply voltage is 100V–240V +/-10%.
The inrush current is actively limited to 13A peak at 230V (6.5A at 115V) per internal PSU.
This much reduces the chance of a nuisance trip or fuse blow from a hot start after a momentary
brownout or blackout of the AC power. The total peak inrush current and quiescent current can
be specified for any size of console. There is a peak operating current when the motorised faders
move. The worst case is if all the faders move end to end where the peak power will be 4 Watts per
fader for <120ms.
Active PFC (Power Factor Correction) is employed in the power supplies and the PF (Power
Factor) is typically greater than 0.88 dependant on console size
The Heat output from the console is typically 0.9 times the RMS VA (Volts x Amperes).
These figures can be provided for any size of console.
The PSU efficiency under all operating conditions is typically greater than 85%, dependant on
console size.
The control surface is cooled by natural air convection. The air intake is on the underside of the
console and the outtake is along the top rear of the console. At least 50mm (2') clearance must
be maintained for these vents.
Short Term: 5°C - 35°C
Long Term: 15°C - 30°C
5% – 80% Non-condensing