7.2.2. Ethernet TCP communication

The inverter can communicate via Ethernet TCP. For installations with more than one inverter, for the first inverter
to communicate with the other inverters, they use the RS-485.
After making the connections in the connector shown in the figure above, the Ethernet cable will leave the unit
through the M20 cable gland supplied with the accessory to be installed in the dedicated wiring access. If RS-485
communication is used, the wiring will leave the unit through the M16 cable gland supplied with the accessory to
be installed in the dedicated wiring access.
To ensure the unit's level of protection, follow the permitted diameter range indicated in section "2.10. Description
of wiring inlets".
ABE2011IQM01_C - Installation and Operation Manual