Installation Instructions
AMP‐to‐NPM Cabling
Note:
The AMP-to-NPM cabling described in this section applies only to VMG-14+ system loaded with
a pair of VMG GEN 1 NPM cards.
Once the AMP card is installed, use the cable Ethernet cable provided by Imagine Communications to
connect the AMP card to its corresponding NPM card:
Connect the AMP card in slot 3 to the NPM in slot 1.
Connect the AMP card in slot 4 to the NPM in slot 2.
Connect the Ethernet cable to ETH 1 on the AMP and GigE port 8 on the NPM.
Connect the Ethernet cable to ETH 2 on the AMP and GigE port 7 on the NPM.
Figure 35
shows the front panel connections for a 2-NPM or NPM2 /2-AMP configuration at the
Selenio VMG.
Figure 35.
AMP Connections to an NPM or NPM2 Pair in the VMG-14+
Selenio
TM
VMG-14+ Hardware Setup Guide
Additional information about AMP setup is
available in the Application Media Processor
(AMP Installation Guide for VMG Systems (part
number 250-0104-01).