Specifications
Digital output
Programmable digital/pulse outputs
Terminal number
Voltage level at digital/frequency output
Maximum output current (sink or source)
Maximum load at frequency output
Maximum capacitive load at frequency output
Minimum output frequency at frequency output
Maximum output frequency at frequency output
Accuracy of frequency output
Resolution of frequency outputs
1) Terminals 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control card, 24 V DC output
Terminal number
Output voltage
Maximum. load
The 24 V DC supply is galvanically isolated from the supply voltage (PELV), but has the same potential as the analog and digital
inputs and outputs.
Relay outputs
Programmable relay outputs
Relay 01 Terminal number (D-frame)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Minimum terminal load on 1–3 (NC), 1–2 (NO)
Environment according to EN 60664-1
Relay 01 terminal number (E-frame and F-frame)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Relay 02 terminal number
Maximum. terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Maximum terminal load (AC-1)
Maximum terminal load (AC-15)
Maximum terminal load (DC-1)
Maximum terminal load (DC-13)
Minimum terminal load on 1–3 (NC), 1–2 (NO), 4–6 (NC), 4–5 (NO)
Environment according to EN 60664-1
1) IEC 60947 parts 4 and 5.
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).
2) Overvoltage Category II.
3) UL applications 300 V AC 2 A.
MG16I302
Operating Instructions
1)
on 1–2 (NO) (Resistive load)
on 1–2 (NO) (Inductive load @ cosφ 0.4)
1)
1)
on 1–2 (NO) (Resistive load)
1)
on 1–2 (NO) (Inductive load)
1)
on 1–3 (NC) (Resistive load)
on 1–3 (NC) (Inductive load @ cosφ 0.4)
1)
1)
on 1–3 (NC) (Resistive load)
1)
on 1–3 (NC) (Inductive load)
1)
on 1–3 (NC), 1–2 (NO) (resistive load)
(inductive load @ cosφ 0.4)
1)
1)
on 1–2 (NO), 1–3 (NC) (resistive load)
1)
(inductive load)
1)
on 4–5 (NO) (resistive load)
on 4–5 (NO) (inductive load @ cosφ 0.4)
1)
1)
on 4–5 (NO) (resistive load)
1)
on 4–5 (NO) (inductive load)
1)
on 4–6 (NC) (resistive load)
on 4–6 (NC) (inductive load @ cosφ 0.4)
1)
1)
on 4–6 (NC) (resistive load)
1)
on 4–6 (NC) (inductive load)
Danfoss A/S © 04/2015 All rights reserved.
2 on both frequency converter and active filter
2)3)
overvoltage category III/pollution degree 2
2)3)
overvoltage category III/pollution degree 2
27 and 29
0-24 V
40 mA
1 kΩ
10 nF
0 Hz
32 kHz
Maximum error: 0.1% of full scale
12 bit
24 V (+1, -3 v)
200 mA
2 on frequency converter only
1–3 (break), 1–2 (make)
400 V AC, 2 A
240 V AC, 0.2 A
80 V DC, 2 A
24 V DC, 0.1 A
240 V AC, 2 A
240 V AC, 0.2 A
50 V DC, 2 A
24 V DC, 0.1 A
24 V DC 10 mA, 24 V AC 2 mA
1–3 (break), 1–2 (make)
240 V AC, 2A
240 V AC, 0.2 A
60 V DC, 1 A
24 V DC, 0.1 A
4–6 (break), 4–5 (make)
400 V AC, 2 A
240 V AC, 0.2 A
80 V DC, 2 A
24 V DC, 0.1 A
240 V AC, 2 A
240 V AC, 0.2 A
50 V DC, 2 A
24 V DC, 0.1 A
24 V DC 10 mA, 24 V AC 20 mA
1)
13
8
8
93

Advertisement

Table of Contents
loading

Table of Contents