Technical specifications
7.4 Technical data
7.4.2
Ambient conditions
Climatic ambient conditions
The temperature values have been checked in accordance with IEC 60068-2-1,
IEC 60068-2-2 and IEC 60068-2-14. For permitted mounting positions, see section
"Preparing installation".
Note
Installation at temperatures > 50 °C in RAL only
If you wish to install the device at an ambient temperature of > +50 °C, you will have have to
install it in a Restricted Access Location (RAL) such as a lockable control cabinet.
All device versions with HDD
USB load max. 6 W
Operation, USB load max. 6 W:
•
•
Operation, USB load max. 6 W:
•
•
Storage/transport
Gradient
Relative humidity
•
•
Barometric pressure
•
•
102
Basic device
PCIe device version, load max. 5 W
Basic device
PCIe device version, load max. 3 W
Operation
Storage/transport
Operation
Storage/transport
+5 ... +40 °C, horizontal and vertical installation
0 ... +50 °C applies to device with:
CFast card, SSD
•
horizontal and vertical installation
•
0 ... +60 °C applies to device with:
CFast memory card
•
horizontal installation only
•
-20 ... +70 °C
Operation: Max. 10 °C/h
•
Storage: 20 °C/h, no condensation
•
Tested in accordance with IEC 60068-2-78,
IEC 60068-2-30
5 ... 85 % at 30 °C, no condensation
5 ... 95 % at 25/55 °C, no condensation
1080 to 795 hPa, corresponds to an elevation of -
1000 to 2000 m
1080 to 660 hPa, corresponds to an elevation of -
1000 to 3500 m
Operating Instructions, 11/2016, A5E35782395-AB
SIMATIC IPC227E