5.4. 2nd LEVEL PROGRAMMING

To access 2nd LEVEL PROGRAMMING, press push-button F
and, while holding it down, press push-button +:
• if you release the + push-button, the display shows the
name of the first function.
• if you also release the F push-button, the display shows the
value of the function, which can be changed with keys +
and -.
• if you press the F key (and hold it down), the display shows
the name of the next function; if you release it, the value
is shown and can be modified with keys + and -.
• when you reach the last function, press push-button F to
exit programming, and the display resumes showing the
inputs status.
2ND LEVEL PROGRAMMING
Display Function
MAXIMUM THRUST TORQUE:
bo
the motor runs at maximum torque (ignoring
torque regulation) at the initial moment of
movement.
Y
= Active
no
= Excluded
PRE-FLASHING:
PF
it permits activation of the flashing lamp for 5
secs before the start of movement.
no
excluded
OC
before each movement
PA
at end of pause only
CL
before closing
SLOW CLOSING:
SC
for setting the entire closing stage at slow
speed.
Y
= Active
n o
= Excluded
DECELERATION TIME AFTER LIMIT SWITCHES:
tr
for setting the deceleration time (in seconds)
after the opening and closing limit switches
have operated.
Can be adjusted from 0 to 10 sec. in 1 second
steps.
0 0
= deceleration excluded
1 0
= maximum deceleration
WORK TIME (time-out):
t
A value should be set from 5 to 10 seconds
longer than the time required for the automated
system to move from the closed position to the
open position, and vice-versa.
Can be adjusted from
steps.
Subsequently, the display changes to show
minutes and tenths of a second (separated by
a dot) and time is adjusted in 10 second steps,
up to the maximum value of 4.1 minutes.
FAIL SAFE:
FS
If this function is activated, it enables a function
test of the photocells before any automated
system movement, independently of the
output used. If the test fails, the automated
system does not start the movement.
Y
= Active
no
= Excluded
De-
fault
Y
no
no
03
20
0
59
to
sec. in 1 second
no
OUTPUT 1:
o 1
The output can be set to one of the following
functions:
00
FAILSAFE
0 1
INDICATOR LIGHT (lighted at
opening and pause, flashing at
closing and off when automated
system closed).
02
BEAM LIGHTING (output active
with beam closed and on pause,
inactive with beam open, flashing
during movement)
03
beam CLOSED
04
beam OPEN or in PAUSE, it goes off
during closing pre-flashing.
05
beam MOVING AT OPENING,
pre-flashing included.
06
beam MOVING AT CLOSING, pre-
flashing included.
07
beam STILL
08
beam in EMERGENCY status
09
LOOP1 engaged
10
LOOP2 engaged
1 1
OPEN for 624 SLAVE
12
CLOSE for 624 SLAVE
13
beam DETACHED
14
FAAC-CITY lights
15
FAAC-CITY buzzer
16
FCA engaged
17
FCC engaged
18
interlock
OUTPUT 1 POLARITY:
P 1
For configuring the output polarity status.
Y
= N.C. polarity
n o
= N.O. polarity
Note: if the output is set to FAIL-SAFE (
leave the default value
OUTPUT 2:
o 2
See output 1
OUTPUT 2 POLARITY:
P 2
See output 1 polarity
OUTPUT 3:
o 3
See output 1
OUTPUT 3 POLARITY:
P 3
See output 1 polarity
OUTPUT 4 / BUS:
o 4
00
If set at
the output is dedicated to
accessories with BUS technology. Refer to
chapter 4.3 on page 5 for an explanation.
This output retains the possibility of
configuration of output 1 with the exception
1 1 , 12
of functions
no effect.
OUTPUT 4 POLARITY:
P 4
For configuring the output polarity status.
Y
= N.C. polarity
n o
= = N.O. polarity (for BUS)
9
00