= Information regarding personal safety and proper maintanence of the product. = Information regarding the product’s characteristics or operation. 455 D Control Board - Rev: 01 - October 2010 455 D Co ntr o l Bo a r d (800) 878-7829...
OPEN A cells and safety 12 V AC OPEN B devices, see Section 13.4.1. LIMIT-SWITCH STOP OR GATECODER Figure B NB: Capacitors are supplied with the operator. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
Page 4
(walls, etc) against the closing areas against the risk of impact. risk of impact and crushing. FAAC recommends use of the lay-out in Fig. D (in the event of fixed obstacles at opening) or in Fig. E (no fixed obstacles).
Page 5
Can be used in single-leaf configuration COM / OP / CL: Connection to Motor 2 Cannot be used in single-leaf configurations LAMP: Flashing lamp output ( AC V ~) Figure J 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
Page 6
LOCK - Power supply to electric lock If necessary, connect a 12 VAC electric strike lock between this terminal and the +24V power supply. Please refer to Chapter 16 for Magnetic Lock connection. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
One to open and one to close. No pressure on a switch stops the gate. Exit from programming and return to inputs status monitoring. If using hydraulic operators, set force to maximum level. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
Page 8
To restore programming defaults, press and hold the three buttons +, -, F simultaneously for 5 seconds. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
1.6.2 Rotation Direction and Force Check Notes: 1. Program the functions of the 455 D control board according to • If you wish to eliminate deceleration in certain stages, wait for the need, as previously shown.
When you are finished programming, test the system. Verify that the entire system operates correctly. Most importantly, check that force is adequately adjusted and that safety devices are operating correctly. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
(2) If a new pulse occurs within 2 seconds after reversing, it immediately stops operation. (3) During the partial opening cycle, an OPEN A pulse causes total opening. NB.: Effects on other active pulse inputs in brackets. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
Page 12
(2) If a new pulse occurs within 2 seconds after reversing, it immediately stops operation. (3) During the partial opening cycle, an OPEN A pulse causes total opening. NB.: Effects on other active pulse inputs in brackets. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
AC input wires. Connect the AC input wires to the AC terminal located on the top left of the enclosure. See diagram on the right. 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...
Neither FAAC S.p.A. nor FAAC International, Inc., shall be liable for any loss or damage whatsoever resulting, directly or indirectly, from the use or loss of use of the product(s). Without 455 D Co ntr o l Bo a r d (800) 878-7829 www.FastGateOpeners.com...