1.

WARNINGS

Attention: Before attempting any work on the control unit (connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
- Connect the earth cable to the terminal on the J9 connector of the unit (see fig.2).
- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electrical
noise, use separate sheaths or a screened cable (with the screen earthed)
2.

TECHNICAL SPECIFICATIONS

230 V~ (+6% -10%) - 50/60 Hz
Power supply
voltage *
115 V~ (+6% -10%) - 50/60 Hz
Absorbed power
Motor max. load
Power supply
for accessories
Accessories max.
current
Operating ambient
temperature
F1 = F 5A - 250V F2 = T 0,8A - 250V
Protection
fuses *
F1 = F 10A - 120V F2 = T 0,8A - 120V
Work time
Programmable (from 0 to 4 minutes)
Programmable (from 0 to 4 minutes)
Pause time
Motor power
3 programming levels for greater
Programming
Coupling for 5-pin Minidec board,
Rapid connector
Programmable
outputs
multifunction display, BUS technology
Features
and INTEGRATED METALLIC MASS
* The power supply voltage and fuses depend on the version
purchased
CONTROL UNIT
or
7 W
300 W
24 Vdc
500 mA
from -20°C to +55°C
or
Programmable on 50 levels
flexibility of use
Decoder, Receiver RP/RP2
4 programmable outputs
in 18 different functions
Management of slow-downs,
DETECTOR
624 BLD
.
3.

LAYOUT AND COMPONENTS OF 624BLD

3.1 DESCRIPTION OF COMPONENTS

DL
SIGNALS AND PROGRAMMING DISPLAY
LED
INPUT STATUS CONTROL LEDs
J1
LOW-VOLTAGE TERMINAL BOARD
TERMINAL BOARD FOR CONNECTION OF MOTOR, FLASHING
J2
LAMP AND FAN
J3
OPENING LIMIT-SWITCH CONNECTOR
J4
CONNECTOR FOR DECODER MINIDEC / RP RECEIVER
J5
CLOSING LIMIT-SWITCH CONNECTOR
J6
CONNECTOR FOR ROD BREAKING SENSOR
CONNECTOR FOR MOTOR THRUST CAPACITOR
J8
J9
TERMINAL-BOARD FOR 230 VAC POWER SUPPLY
LOOP 1 and LOOP 2 FREQUENCIES SELECTOR
DS1
F1
FUSE FOR MOTORS AND TRANSFORMER PRIMARY WINDING (F 5A)
F2
FUSE FOR LOW VOLTAGE AND ACCESSORIES (T 800mA)
F
PROGRAMMING PUSH-BUTTON "F"
+
PROGRAMMING PUSH-BUTTON "+"
-
PROGRAMMING PUSH-BUTTON "-"
TF1
TRANSFORMER
3
Fig. 1