FAAC 624 BLD Manual page 19

Control board
Hide thumbs Also See for 624 BLD:
Table of Contents

Advertisement

Tab. 1/d
LOGIC "P"
AUTOMATED SYSTEM
OPEN A
STATUS
CLOSED
OPENING
no effect
no effect
OPEN
(closing
disabled)
reverses
CLOSING
immediately at
opening
STOPPED
Tab. 1/e
LOGIC "PA"
AUTOMATED SYSTEM
OPEN A
STATUS
opens and
CLOSED
re-closes after
pause time
OPENING
no effect
recharges pause
OPEN IN PAUSE
reverses
CLOSING
immediately at
opening
opens and
STOPPED
re-closes after
pause time
Tab. 1/f
LOGIC "Cn"
AUTOMATED SYSTEM
OPEN A
STATUS
CLOSED
OPENING
no effect
no effect
OPEN
(closing
disabled)
reverses
CLOSING
immediately at
opening
STOPPED
In brackets the effects on the other active pulse inputs
CLOSE
opens
no effect
closes
immediately at
end of opening
closes
no effect
opens
closes
CLOSE
no effect
closes
immediately at
end of opening
closes
time
no effect
closes
CLOSE
opens
no effect
closes
immediately at
end of opening
closes
no effect
opens
closes
PULSES
STOP
FSW
no effect
no effect
(opening
disabled)
stops
no effect
operation
no effect
no effect
(closing
(closing
disabled)
disabled)
stops and
stops
continues to
operation
close on release
no effect
no effect
(opening and
(closing
closing disabled)
disabled)
PULSES
STOP
FSW
no effect
(opening
no effect
disabled)
stops
no effect
operation
recharges pause
stops
time
operation
(closing
disabled)
stops and
stops
continues to
operation
close on release
no effect
no effect
(opening and
(closing
closing disabled)
disabled)
PULSES
STOP
FSW
no effect
(opening
no effect
disabled)
stops
no effect
operation
no effect
no effect
(closing
(closing
disabled)
disabled)
reverses at
stops
opening and
operation
closes after
pause time
no effect
no effect
(opening and
(closing
closing disabled)
disabled)
18
LOOP 1
LOOP 2
opens and at end
of opening closes
no effect
if disengaged
closes
no effect
immediately at
end of opening
prevents closure
closes
reverses
immediately at
stops and
opening and
continues to
closes at end
close on release
of opening if
disengaged
opens and at end
no effect
of opening closes
(closing
if disengaged
disabled)
LOOP 1
LOOP 2
opens and at end
of opening closes
no effect
if disengaged
closes
no effect
immediately at
end of opening
recharges pause
closes
time
reverses
immediately at
stops and
opening and closes
continues to
at end of opening if
close on release
disengaged
opens and at end
no effect
of opening closes
(closing
if disengaged
disabled)
LOOP 1
LOOP 2
opens
no effect
closes
no effect
immediately at
end of opening
no effect
closes
reverses
reverses
immediately at
immediately at
opening
opening
no effect
opens
(closing
disabled)

Hide quick links: