FAAC 624BLD Manual
Hide thumbs Also See for 624BLD:

Advertisement

1... WARNINGS........................................................................................................................................................... 3
2... TECHNICAL.SPECIFICATIONS. . ............................................................................................................................... 3
3... LAYOUT.AND.COMPONENTS.OF.624.BLD. . ............................................................................................................ 3
3.1. . Description.of.components. . .................................................................................................................................. 3
4... ELECTRICAL.CONNECTIONS. . ................................................................................................................................ 4
4.1..Connection.of.photocells.and.safety.devices....................................................................................................... 4
4.2..J1.Terminal-board.-.Accessories.(Fig.2)................................................................................................................. 5
4.3..J2.Terminal-board.-..motor.-.flashing.light.and.fan.(Fig.2).................................................................................... 5
4.4..J8.Connector.-.Motor.capacitor.(Fig.2)................................................................................................................. 5
4.5..J9.Terminal-board.-.Power.supply.(Fig.2)............................................................................................................... 5
4.6..J3,.J5.Rapid.connectors.-.for.opening.and.closing.limit-switches.(Fig.2). . ............................................................ 5
4.7..J6.Connector.-.Beam.breaking.sensor.(Fig..2). . ..................................................................................................... 6
4.8..J11a,b,c.Connector.-.Quick-fit.connector.for.external.loop.detector.(Fig.2)....................................................... 6
4.9...J4.Quick.fit.Connector.-..for.Minidec,.Decoder.and.RP....................................................................................... 6
5... PROGRAMMING................................................................................................................................................... 6
5.1..1ST.LEVEL.PROGRAMMING. . .................................................................................................................................... 6
5.2..2nd.LEVEL.PROGRAMMING..................................................................................................................................... 7
5.3..3rd.LEVEL.PROGRAMMING. . .................................................................................................................................... 8
5.4..MODIFICATION.OF.FUNCTION.LOGIC...................................................................................................................... 9
5.5..MODIFICATION.OF.PRE-SETTING.OF.LOGICAL.PARAMETERS. . ................................................................................... 10
6... START-UP............................................................................................................................................................... 10
6.1..LEDS.CHECK............................................................................................................................................................ 10
7... AUTOMATED.SYSTEM.TEST..................................................................................................................................... 10
8... MASTER-SLAVE...................................................................................................................................................... 11
9... FUNCTION.LOGICS.TABLES.................................................................................................................................... 12.
INDEX


Advertisement

Table of Contents
loading

Summary of Contents for FAAC 624BLD

  • Page 1: Table Of Contents

    INDEX 1... WARNINGS................................3 2... TECHNICAL.SPECIFICATIONS..........................3 3... LAYOUT.AND.COMPONENTS.OF.624.BLD......................3 3.1. . Description.of.components............................ 3 4... ELECTRICAL.CONNECTIONS..........................4 4.1..Connection.of.photocells.and.safety.devices....................... 4 4.2..J1.Terminal-board.-.Accessories.(Fig.2)......................... 5 4.3..J2.Terminal-board.-..motor.-.flashing.light.and.fan.(Fig.2)..................5 4.4..J8.Connector.-.Motor.capacitor.(Fig.2)......................... 5 4.5..J9.Terminal-board.-.Power.supply.(Fig.2)....................... 5 4.6..J3,.J5.Rapid.connectors.-.for.opening.and.closing.limit-switches.(Fig.2).............. 5 4.7..J6.Connector.-.Beam.breaking.sensor.(Fig..2)....................... 6 4.8..J11a,b,c.Connector.-.Quick-fit.connector.for.external.loop.detector.(Fig.2)............
  • Page 2 0) The installer shall supply all information concerning manual operation of the system in case of an emergency, and shall hand over to the user the 6) FAAC declines all liability caused by improper use or use other than that for warnings handbook supplied with the product.
  • Page 3: Warnings

    Automatic, Automatic , Semiautomatic, Parking, Parking-Automatic, F u n c t i o n l o g i c s Condo, Condo-automatic FAAC-CITY, Dead-man, Remote, Custom EMERG - DL5 Programmable (from 0 to 4 minutes) W o r k t i m e...
  • Page 4: Electrical.connections

    4.. ELECTRICAL.CONNECTIONS BEAM BREAKING MOTOR THRUST CAPACITOR 10 11 12 13 16 17 24Vdc MOTOR To connect the 230Vac photocells and max 60W safety devices, 230Vac consult paragraph 50Hz 4.1. OPEN STOP CLOSE Fig. 2 EMERGENCY 4.1.CONNECTION.OF.PHOTOCELLS.AND.SAFETY.DEVICES Connection of two pairs of closure photocells Before you connect the photocells (or other devices) we advise you to select the type of operation according to the movement zone they have to protect.
  • Page 5: J1.Terminal-Board.-.Accessories.(Fig.2)

    Connection of one safety device (teminals 10-11-19) - Negative contact for feeding accessories 24 Vdc (terminals 12-13) - Positive contact for feeding accessories . Max.. load. of. accessories:. 500. mA.. To. calculate. 10 11 12 13 16 17 absorption. values,. refer. to. the. instructions. for. individual.accessories.
  • Page 6: J6.Connector.-.Beam.breaking.sensor.(Fig

    If using a single-channel RP type receiver, only OPEN can be Default FAAC  loaded commanded. Default FAAC CITY loaded Fit the accessory with the components side directed toward the board Default FAAC CITY K loaded interior. For an explanation of the parameter, . Insert.and.remove.the.boards.ONLY.after.cutting.
  • Page 7: 2Nd.level.programming

    + and -. CLOSE for 64 SLAVE Beam DETACHED • when you reach the last function, press the F push-button FAAC - CITY lights to exit programming, and the display resumes showing the FAAC - CITY buzzer inputs status. FCA engaged...
  • Page 8: 3Rd.level.programming

    LEVEL PROGRAMMING 10sec Display Function Default OUTPUT 4: Default 00, 11 , Display Function / setting See output  , except to functions that in this case have not effect. If you enable this function, automatic closure = automatic occurs after pause time.. closure = disables OUTPUT 4 POLARITY:...
  • Page 9: Modification.of.function.logic

    SAFETY ONLY PRESSURE SWITCH FOR FAAC CITY: Recognition of PHOTOCELL contact as a safety = disables PRESSURE SWITCH but not as TL for FAAC CITY If you enable this function, and if parameter = closure at = Operation with dedicated mechanical tra-...
  • Page 10: Modification.of.pre-Setting.of.logical.parameters

    For example, if you choose and exiting from st level programming, all the FAAC default values which can be found in tables of st, nd and START-UP 3rd level in the “Default” column are loaded. In this way, all the parameters in the memory are returned to a known 6.1..
  • Page 11: Master-Slave

    .8.. MASTER-SLAVE 624BLD 624BLD SLAVE MASTER 10 11 12 13 16 17 10 11 12 13 16 17 P2 no OUT2: Logica per il resto lasciare il default Logic for the rest leave the default o3 12 P3 no LO C Logique pour le reste laisser par défaut...
  • Page 12 Tab. 1/a LOGIC “A” PULSES AUTOMATED SYSTEM OPEN A CLOSE STOP LOOP 1 LOOP 2 STATUS no effect opens and closes after opens and closes after CLOSED no effect (opening disabled) no effect no effect pause time pause time reverses OPENING no effect immediately at...
  • Page 13 Tab. 1/d LOGIC “P” PULSES AUTOMATED SYSTEM OPEN A CLOSE STOP LOOP 1 LOOP 2 STATUS opens and at end no effect CLOSED opens no effect no effect of opening closes if no effect (opening disabled) disengaged closes immediately closes immediately OPENING no effect stops operation...
  • Page 14 Tab. 1/g LOGIC “CA” PULSES AUTOMATED SYSTEM OPEN A CLOSE STOP LOOP 1 LOOP 2 STATUS no effect opens and closes after opens and closes after CLOSED no effect no effect no effect pause time pause time (opening disabled) closes immediately closes immediately OPENING no effect...

Table of Contents