FAAC 624 BLD Manual page 20

Control board
Hide thumbs Also See for 624 BLD:
Table of Contents

Advertisement

Tab. 1/g
LOGIC "CA"
AUTOMATED SYSTEM
OPEN A
STATUS
opens and
CLOSED
re-closes after
pause time
OPENING
no effect
recharges pause
OPEN IN PAUSE
reverses
CLOSING
immediately at
opening
opens and
STOPPED
re-closes after
pause time
Tab. 1/h
LOGIC "rb"
AUTOMATED SYSTEM
OPEN A
STATUS
opens and
CLOSED
re-closes after
pause time
OPENING
no effect
recharges pause
OPEN IN PAUSE
reverses
CLOSING
immediately at
opening
opens and
STOPPED
re-closes after
pause time
Tab. 1/i
LOGIC "C"
AUTOMATED SYSTEM
OPEN A
STATUS
CLOSED
OPENING
no effect
OPEN
(closing
disabled)
reverses
CLOSING
immediately at
opening
STOPPED
In brackets the effects on the other active pulse inputs
CLOSE
no effect
closes
immediately at
end of opening
closes
time
no effect
closes
CLOSE
no effect
reverses
immediately at
closing
closes
time
no effect
closes
MAINTAINED COMMANDS
CLOSE
opens
no effect
/
no effect
closes
/
opens
closes
PULSES
STOP
FSW
no effect
(opening
no effect
disabled)
stops
no effect
operation
recharges pause
stops
time
operation
(closing
disabled)
reverses at
stops
opening and
operation
closes after pause
time
no effect
no effect
(opening and
(closing
closing disabled)
disabled)
PULSES
STOP
FSW
no effect
(opening
no effect
disabled)
stops
no effect
operation
recharges pause
stops
time
operation
(closing
disabled)
reverses
stops
immediately at
operation
opening
no effect
no effect
(opening and
(closing
closing disabled)
disabled)
STOP
FSW
no effect
(opening
no effect
disabled)
stops
no effect
operation
stops
no effect
operation
stops
Stops
operation
operation
no effect
no effect
(opening and
(closing
closing disabled)
disabled)
19
LOOP 1
LOOP 2
opens and
re-closes after
no effect
pause time
no effect
immediately at
end of opening
recharges pause
time
reverses
reverses
immediately at
immediately at
opening
opening
opens and
no effect
re-closes after
pause time
disabled)
LOOP 1
LOOP 2
opens and
re-closes after
no effect
pause time
no effect
no effect
recharges pause
recharges pause
time
(closing
disabled)
reverses
reverses
immediately at
immediately at
opening
opening
opens and
no effect
re-closes after
(closing
pause time
disabled)
PULSES
LOOP 1
LOOP 2
no effect
no effect
no effect
no effect
no effect
no effect
(closing
(closing
disabled)
disabled)
stops
operation
operation
no effect
no effect
(closing
(closing
disabled)
disabled)
closes
closes
(closing
time
stops

Hide quick links: