Setup For Integrated Loop Detector - FAAC 624 BLD Manual

Control board
Hide thumbs Also See for 624 BLD:
Table of Contents

Advertisement

ASSISTANCE REQUEST (coupled to the next
A S
two functions):
If activated at the end of the count-down
(settable with the next two functions under
"Cycle programming"), it activates LAMP
output for 4 sec every 30 sec. (assistance
request). Can be useful for setting scheduled
maintenance.
Y
= Active
no
= Excluded
CYCLE PROGRAMMING IN THOUSANDS:
n c
For setting a count-down of the system
operating cycles, settable value from 0 to 99
(thousands of cycles). The displayed value is
reset as the cycles progress, interacting with
nC
the
value (99
n C
correspond to one
The function can be used combined with nC,
to check the use of the system and to make
use of the "Assistance request".
CYCLE PROGRAMMING IN HUNDREDS OF
n C
THOUSANDS:
For setting a count-down of the system
operating cycles, settable value from 0 to
99 (hundreds of thousands of cycles). The
displayed value is reset as the cycles progress,
interacting with the
nC
corresponds to 99
The function can be used combined with
to check the use of the system and to make
use of the "Assistance request".
HOLD TIME LOOP 1
h 1
For setting the presence time on loop 1. At
the end of this time the board calibrates itself
and indicates "loop free" (decimal point of
the units OFF). On switching on the board, an
automatic reset is performed.
Y
no
HOLD TIME LOOP 2
h2
For setting the presence time on loop 2. At
the end of this time, the board calibrates itself
and indicates "loop free" (decimal point of
the tens OFF). On switching on the board, an
automatic reset is performed.
Y
no
AUTOMATED SYSTEM STATUS:
St
Exit
programming,
data and return to gate status display (see
paragraph 5.1.).

5.5. SETUP FOR INTEGRATED LOOP DETECTOR

The 624 BLD is equipped with an integrated metallic mass
detector for induction detection of vehicles.
Features:
galvanic separation between the electronics of the detector
and of the loop
automatic alignment of the system immediately after
activation
continual resetting of frequency drifts
sensitivity independent of loop inductivity
regulation of the working frequency of the loops
message of loop engaged with LED display
loop status addressable on the OUT 1, OUT 2, OUT 3 and
OUT 4 outputs
nc
decrementing steps
decrement).
nc
n c
. (1
decrement
decrementing steps).
n c
,
= 5 minutes
= infinite
= 5 minutes
= infinite
memory
storage
of
Connection:
no
Connect the loop detectors as indicated in figure 2 on page
4:
- Terminals 1 - 2 for LOOP 1 = loop with opening function;
- Terminals 3 - 4 for LOOP 2 = loop with closing and/or closing
safety function.
To learn more about the effect of signals originating from the
loops on the automated system, please refer to the logic
tables in chapter 12.
00
To enable the function of the connected loops, enter the
1st programming level and set steps
enable the function of the connected loops, enter the 1st
programming level and set steps.
The operating status of the loop detector is shown through the
use of decimal points on the display when automated system
status is displayed (step
CALIBRATION
0 1
Each time the 624 BLD board is powered,
the display shows the automated system
status and the integrated loop detector
calibrates the connected loops. Therefore,
perform a calibration, removing power from
the 624 BLD for at least 5 seconds.
Calibration is shown on the display through
flashing of the two points, as in figure 15.
no
If one or both the magnetic loops are not installed,
the loop detector is continually calibrated without
this creating problems to the functioning of the
board. Therefore, during display of the automated
system status, one or both the decimal points will
flash constantly.
Once calibration has taken place, the decimal points indicate
no
the loop status:
LOOP 1
Point ON
Point OFF
Point FLASHING
REGULATION OF SENSITIVITY
Regulating the sensitivity determines the variation of the
inductivity, for each channel, which a vehicle must cause to
activate the relative output of the detector.
Regulation of the sensitivity is performed separately for each
channel with the aid of the two
1st programming level. Consult chapter 5.1
REGULATION OF HOLD TIME
The retaining time count starts on engagement of the loop.
If, on expiry of this time, the loop is still engaged, a new
calibration is performed automatically where the presence
of the metallic mass on the loop no longer causes its
engagement. At the end of the new calibration, the loop is
considered "disengaged".
The retaining time can be regulated with the aid of the two
h 1
h2
and
parameters at the 2nd programming level.
Consult chapter 5.4
10
L1
and
St
).
Fig. 15
= Loop ENGAGED
= Loop DISENGAGED
= Loop NOT CONNECTED or BEING CALIBRATED
S1
S2
and
parameters at the
L2
Y.
in
To
LOOP 2