Control Panel - Atlas Copco XAHS 70 KD8 WUX Instruction Manual

Portable compressors
Table of Contents

Advertisement

CONTROL PANEL

(P1)
(H2)
(PG)
(F1)
(H1)
Reference
Name
P1
Hour meter
F1
Main switch
PG
Working pressure gauge
H1
General alarm lamp (red)
H2
Temperature alarm lamp (red)
S1
Start switch with pre-heating
position
The main switch is a protection against
unintended starting of the compressor.
STARTING PROCEDURE
(S1)
1
2
3
4
5
MAX
10 SEC
6
7
ON
8
3 MIN
9
20 SEC
- 25 -
Before operating the unit first read the manual.
1. Open air outlet valve, do not connect a hose yet.
2. Open the hood and switch the main switch at the
back of the control panel to ON.
3. Turn the start switch S1 clockwise to position 1,
lamp H2 (temperature alarm lamp) will go on.
4. To preheat turn the start switch S1 clockwise to
position 2 for 20 sec (also to allow the fuel pump
priming).
5. Turn start switch S1 further clockwise into
position 3. The general alarm lamp H1 will go on.
The starter motor will set the engine in motion.
The maximum allowed starter time, where the
starter motor is running continuously, is
10 seconds. If the engine does not catch, a new
attempt can be made after waiting 30 seconds.
General alarm lamp H1 will go out as soon as the
engine has been started.
6. The start switch automatically springs back to
position 1 and both lamps will be off.
7. Close the air outlet valve(s).
8. Let the engine warm up for 3 minutes.
9. After warming up the air hose can be connected
and the unit is ready for operation.
Lamp H2 will only come on when the
compressor outlet temperature is too
high.