Security Codes and Authority Levels (cont'd)
T o A d d a U s e r
IMPORTANT!
Temporary users should not be shown how to use any system function they do not need to
know (e.g. bypassing protection zones).
1.
Enter Master or Manager code +
2.
Enter the new user's 3-digit User Number (002-250).
3.
Enter 4-digit security code for that user.
Assuming you want to program user 003 as 5678 using the master code of 1234, the syntax reads as
follows:
8
1234 +
+ 003 + 5678
CODE
Once entered the following prompts will appear.
ADD NEW USER?
0 = NO , 1 = YES
USER NUMBER = 003
ENTER AUTH. LEVEL
Group BYPASSING?
0 = NO , 1 = YES
Access Group?
Enter 0-8
RF BUTTON ?
0 = NO , 1 = YES
ENTER BUTTON ZN #
(001-250)
8
key.
CODE
Enter 1 to add a new user code.
NOTE: Entering 0 will change the existing user's code to the
code entered in step 3. See Changing A User's Code
section.
Enter the authority level, 1-6, for this user within this partition.
1 = Master
4 = Operator B
Enter 1 (YES) to allow this user to perform group bypasses.
Enter 0 (NO) this user will not be able to perform group
bypasses.
If Access Schedules have been programmed, this prompt
appears. Enter the user's access group number (1-8) if this
user should have limited access to the system.
Enter 0 if no access group should be assigned.
This prompt will appear if a 5800 series wireless key transmitter
has been supplied and has not yet been assigned to a user.
Press 1 if a button transmitter will be assigned to this user.
Otherwise press 0.
NOTE: This requires the three-digit zone number for the
wireless key provided by the installer.
If assigning a wireless key button, this prompt will appear. (Note
each wireless key button is assigned to zone.) Enter the button's
zone number.
NOTE: This requires the three-digit zone number for the
wireless key provided by the installer.
14
2 = Manager
3 = Operator A
5 = Operator C
6 = Duress code