Section 4: Entry/Exit Delays
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
G e n e r a l I n f o r m a t i o n
Your system has installer-programmed time delays, known as Exit Delay and Entry Delay.

Exit Delay

Whenever you arm your system (Away, Stay, Instant, or Maximum), an exit delay gives you time to leave
through the designated exit door without setting off an alarm.
NOTE:
Exit delay begins immediately after entering any arming command, and applies to all modes
of arming protection. If programmed, a slow beeping will sound throughout the exit delay
period.

Entry Delay

An entry delay gives you time to disarm the system when you reenter through the designated entrance
door.
NOTES
The system must be disarmed before the entry delay period ends, or an alarm will occur.
The keypad will beep during the entry delay period, reminding you to disarm the system.
You can also arm the system with no entry delay at all by using either INSTANT or MAXIMUM
arming modes. These modes provide greater security while on the premises or while away for
extended periods of time. See your installer for your delay times.

Defaults and Requirements

As a requirement of SIA-CP-01, Entry Delay is 30 seconds and Exit Delay is 60 seconds.

Exit Delay Reset

As a requirement of SIA-CP-01, an Exit Delay Reset is designed to allow a user to re-enter the premises
to retrieve a forgotten item without triggering an alarm. This feature may only be activated once after
arming.
If enabled, when the panel is armed, the normal exit delay begins. After the user exits, closes the door
and then re-enters the premises, the exit delay time is reset to the programmed value.

Burglar Alarm Communication Delay

As a requirement of SIA-CP-01, there is a communicator delay of 30 seconds in this control panel. This
delay will prevent a report to the central station if the control panel is disarmed within 30 seconds after
an intrusion alarm is triggered. This delay can be removed, or it can be increased up to 45 seconds at
the option of the user by consulting with the Installer. Note that fire-type alarms are normally reported
without delay.