3.1 I Winterising

• Winterising is vital to prevent the condenser breaking due to freezing. This is not covered by
the warranty.
• To avoid damaging the appliance with condensation, do not fully cover it; a winterising cover
is provided.
• Set the regulator to "standby" mode by pressing and holding
• Open valve B,
• Close valves A and C and open valves D and E (if present),
• Make sure that there is no water circulating in the heat pump,
• Drain the water from the condenser (risk of freezing) by unscrewing the two water inlet and outlet connectors on the
back of the heat pump,
• In the case of full winterising for the pool (complete shutdown of the filtration system, bleed the filtration circuit
or even pool drainage): re-fit the two connectors by one turn to prevent any foreign bodies from getting into the
condenser,
• In the case of winterising for the heat pump only (shutdown of the heating only, the filtration keeps running): to not
tighten the connectors but add 2 caps (provided) on the condenser's water inlets and outlets.
• We recommend that you put the aired winterising micro cover (provided) on the heat pump.

3.2 I Maintenance

• Before any maintenance work on the appliance, you must cut the electricity supply as there is
a risk of electric shock which may cause material damage, serious injury or even death.
• Before any maintenance, troubleshooting or repair operation, deactivating the modem's
Wi-Fi connection is recommended to avoid any risk of the appliance being remotely controlled.
• Do not disconnect the electricity supply when the appliance is running.
• If the electric power supply is interrupted, wait a minute before restoring power to the
appliance.
• It is recommended that the appliance undergo general servicing at least on a yearly basis
to ensure proper operation, maintain performance levels and potentially prevent certain
failures. These operations are carried out at the user's expense by a technician.
3.2.1 User maintenance
• Make sure that the ventilation grid is not blocked by any foreign bodies.
• Clean the evaporator (for location see § "5.3 I Dimensions and marking") using a soft brush and a fresh water spray
(disconnect the power cable); do not fold over the metal wings, then clean the condensate drainage line to remove
any impurities that may be blocking it.
• Make sure that the switch box's ventilation grid is clean.
• Do not use a high pressure jet. Do not spray with rain water, salt water or water which is full of minerals.
• Clean the outside of the appliance; do not use any solvent-based products. We can provide you with a specific cleaning
kit as an accessory: the PAC NET, see § "5.1 I Description".
3.2.2 Maintenance to be carried out by a qualified technician
• Check that the control system is operating correctly.
• Check that the condensates flow correctly when the appliance is in operation.
• Check the safety mechanisms.
• Check the connection of the metal masses to the earth.
• Check that the electrical cables are correctly tightened and connected and that the switch box is clean.
17
❸ Maintenance
for 3 seconds and disconnect the power supply,