Outdoor Unit Inspection Points - Mitsubishi SCM40ZS-S Technical Manual

Inverter multi-split system residential air-conditioners
Table of Contents

Advertisement

(12) Outdoor unit inspection points
Models SCM40ZS-S,45ZS-S
CAUTION- HIGH VOLTAGE
High voltage is produced in the control box. Don't touch
electrical parts in the control box for 5 minutes after the
unit is stopped.
Power source
1 Phase
AC220-240V 50Hz
TB1
BK
L
1
WH
N
2
RD
3
UNIT A
Y/G
TB2
BK
1
WH
UNIT B
2
BR
3
◆Voltage check in PCB
The normal range is as follows.
Display
①DC280V DC230V - DC310V
②DC220V DC218V - DC222V
③DC213V DC212V - DC214V
④DC215V DC214V - DC216V
⑤DC225V DC224V - DC226V
⑥DC 2.5V DC 2.3V - DC22.5V
PCB 1(MAIN)
U
V W
M
CM
3~
◆Inspection power transistor
Remove the fasten terminal and test
output voltage
◆Power source and serial signal inspection
① to ②: AC220/230/240V
② to ③ : Normal if the voltage oscillates between
FUSE
250V 15A
BK
R
IN
WH
S
IN
G1
Y/G
G2
Y/G
RD
CNA
BR
CNB
Voltage range
L1
L2
DC0 and approx. 20V
CNMAIN
CN20V
PCB 2(SUB)
CNEEV1
WH
RD
M
M
EEV A
EEV B
◆Inspection of electronic expansion valve
See page 219.
SNSUB
CNFAN
CNTH
2
M
FMo
Tho-R
Tho-A Tho-D
◆Inspection of outdoor
◆Inspection of resistance value of sensor
fan motor
Remove the connector and check the resistance value.
See page 219.
See the section of sensor characteristics on page 209.
217
-
-
'16 • SCM-T-199
Color marks
Mark
Color
BK
Black
RD
Red
WH
White
BL
Blue
BR
Brown
YE
Yellow
Y/G
Yellow/Green
BK
R
O
WH
S
O
WH
S-1
RD
C-1
3
2
S1
R1
C-2
S-2
CN20S
CNHEAT
2
2
2
20S
HEATER
Tho-S

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents