Range Of Usage & Limitations - Mitsubishi SCM40ZS-S Technical Manual

Inverter multi-split system residential air-conditioners
Table of Contents

Advertisement

4. RANGE OF USAGE & LIMITATIONS
Item
Indoor intake air temperature
(Upper, lower limits)
Outdoor air temperature
(Upper, lower limits)
Indoor units
Number of connected units
that can be
used in
Total of indoor Units (class kW)
combination
Total length for all rooms
Length for one indoor unit
When indoor unit is above
Difference in
outdoor unit (A)
height between
indoor and outdoor
When indoor unit is below
units
outdoor unit (B)
Difference in height between indoor units (C)
Compressor
1 cycle time
stop/start
frequency
Stop time
Voltage fluctuation
Power source
Voltage drop during start
voltage
Interval unbalance
Power cable length
Note(1) The cable specifications are based on the assumption that a metal or plastic conduit is used with no more than three cables contained
in a conduit and a voltage drop is 2%. For an installation falling outside of these conditions, please follow the internal cabling
regulations. Adapt it to the regulation in effect in each country.
A
C
B
Model
SCM40ZS-S
Cooling
Heating
Cooling
Heating
4.0-6.0kW
10 min. or more (from stop to stop or from start to start)
126
-
SCM45ZS-S
Approximately 18 to 32℃
Approximately 15 to 30℃
Approximately -15 to 43℃
Approximately -15 to 24℃
2 units
4.5-7.0kW
Max. 30m
Max. 25m
Max. 15m
Max. 15m
Max. 25m
3 min. or more
Within ±10% of rated voltage
Within ±15% of rated voltage
Within ±3% of rated voltage
32m
(1)
-
'16 • SCM-T-199
SCM50ZS-S
2 to 3 units
5.0-8.5kW
Max. 40m