轉性能,在您開始使用空調器之前,務請仔細閱讀本說明書。閱後應將它妥善保 遙控操作失靈時 管好,以備必要時查閱。 緊急運行操作方法 Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES Air -Conditioner. To get 電源中斷自動重新啟動功能 the best long-lasting performance, please read and follow this User’s Manual carefully before 請正確使用 using your air-conditioner. After reading, please store the Manual in a safe place and refer to it 維護保養...
Page 20
Before starting to use the system, please read these “Safety precautions”carefully to ensure properoperation of the system. The safety precautions are classified as “ DANGER”and “ CAUTION” Precautions as shown inthe column “ DANGER” indicate that improper handling could have dramatic Characteristics of HEAT mode operation consequences like death,serious injury, etc.
Page 21
OPERATION PRECAUTIONS The system should only be Do not place anything,co- Do not install the system at used for its original purpose ntaining water,like vases, a place where the air stream Do not expose yourself to t- Do not insert anything into The remote control shall be and not for anything else on top of the unit.
Page 22
PRECAUTIONS FOR TRANSFER OR REPAIRS When loading and unload- Please never damage or Please contact with your di- Consult your dealer for repairs to the sys- If the air conditioner is moved elsewhere, ing the inspiration grid and alter the power line. stributor to clean the internal tem.
Page 23
Choice of operations and features Characteristics of HEAT mode operation Mechanism and capacity of HEAT mode operation Choice of operations The unit draws heat from the cold outside air, transfers it to indoors and heats the room. As a characteristic of heat pump system, the heating capacity reduces when the outside COOL FAN SPEED AUTO...
Page 24
Name of each part and its function Operation and indication section for remote control Unit display section Operation section When each button on the remote control is pressed with the remote control pointing toward the air conditioner unit a signal is transmitted. When the signal is received correctly.The unit will beep.The availability send beeline of the remote control is 5 meters.
Page 25
Indication section Temperature adjustment during AUTO Air temperature adjustment is possible even during automatic operation there are temper- Signal display Indicates set Child lock mode ature of adjustment possible with the button or the button. operation. Displayed when the remote If you want to adjust the temperature, you should make control sends a signal.
Page 26
Air flow direction adjustment procedure Operation condition of the air conditioner Please use within the following operation scope,otherwise it will start the automatic prote- ction device and resist the work of the air conditioner. Adjusting up/down air flow direction COOL operation HEAT operation Up/down direction can be adjusted with the AIR FLOW...
Page 27
SLEEP operation procedure ON-TIMER operation procedure Timing operation includes the setting of on-timer and off-timer. The on-timer function can Aim the remote control at the air conditioner. be set only when the air conditioner is not running. Example:Near set temperature around 8:00 a.m. ON/OFF Aim the remove control at the air conditioner.
Page 28
OFF-TIMER operation procedure Setting method of the current time Timing operation includes the setting of on-timer and off-timer. The off-timer function can The current time will be set to 13:00 auto matically after the battery is installed. When be set only when the air conditioner is running. entering in the time setting,all the contents on the remote controller will be reset.
Page 29
JET operation procedure ECONO operation procedure After the JET function is turned on, the temperature will be automatically compensated on the basis of the original set temperature. The temperature range is between 18 ℃ 30 ℃. ON/OFF The temperature decreases by - 2 ℃ during refrigeration and increases by 2 ℃ during Make the air conditioner operation.
Page 30
How to set the Child Lock Emergency run operation procedure Child lock is set to prevent misuse, which can be made under the ON/OFF state. The “ON/OFF” button on the unit operates “ON/OFF” temporarily when the remote con- trol is not used. Aim the remote control at the air conditioner.
Page 31
Remote control handing procedure When the operation fails with the remote control Replacing the batteries Are the batteries running down? If the operation still fails, handle as per Page58 The following cases signify exhausted batteries.replace old batteries with new ones. Replace the batteries with new emergency run operation.
Page 32
Maintenance At the beginning of the season At the end of the season Make certain that there are no obstac- Set the temperature setting for app- During the operational season Before maintenance les blocking the air flow around the air roximately a half day at 30℃...
Page 33
Installation, inspection and change of the filter screen Installation, inspection and change of the filter screen The air filters clogged with dust, etc., then the cooling / heating capacity will How to open the air inlet panel How to close the air inlet panel NOTE drop, the operation noise increases, power consumption also increases.
Page 34
The following situation is not a failure Has the unit been installed correctly? Suitable installation position The memory circuit of the microcomputer has After a power cut, you cannot restart, been wiped out. Use the remote control to sta- even if power has been restored. rt the operation again.
Page 35
Troubleshooting Self diagnosis function Please carry out the following checks before making a service call. The company always strives to provide the clients with more excellent service and install different judgment systems to display the following abnormal functions (the ones for abn- The air conditioner does not work at all ormal lighting and quenching type are illustrated as follows.
Page 36
Sheet, installation Please read these “safety Precautions” first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, Accessorles list Installation tool (necessary) those points which are related to the strong possibility of an installation done in error resulting in or senous injury are listed in the section.However, there is also a possibility of serious consequences in relationship to the points listed in the...
Page 37
Connect wiring Power cable Model Rated current specification specification SRK25QE3 H05VV-F SRK35QE3 The exhaust port and inspiration port behind the equipment shall be installed 10cm far Color White away from the wall. (If the height of the fence is higher than 1.2m ar above the head, suf- ficient space shall be left between the equipment and the wall.
Page 38
Find the stent, small column and other structural parts of the wall first install and filx more firmly after making en- sure whether the installation place is horizontal. Four screws are used to hor- The center of circle levels with datum line of installation board izontally adjust the installati- on board when it is under the...
Page 39
TERMINAL WIRING COLOR BLACK BLUE BROWN YELLOW/GREEN Connecting line between indoor unit and outdoor unit Drain elbow Cushion rubber Ethylene hose Water shutoff plug Preparation Please notice,when using R410A professional flaring too or common flaring tool, that size B (from the outstanding part of the flaring board) will change, which is determined by the type of the flaring tools.
Page 40
The external insulation belt is The insulator is used to wind the connect- used to wind the outer parts or and then cover adhesive tape on it. and form the piping then to make it match with the cont- Polyvinyl chloride our of the path.
Page 41
After the installation is finished, start up the machine for trail run after inspecting and making sure the following items to make the machine operate normally. Meanwhile, explain the related affairs about the application and maintenance of the machine to the user according to the inshu- ction.
Need help?
Do you have a question about the SRK25QE3 and is the answer not in the manual?