Mitsubishi SCM40ZS-S Technical Manual page 173

Inverter multi-split system residential air-conditioners
Table of Contents

Advertisement

● Since the status of remote control is retained in memory always, it restarts operations according to the contents of memory
as soon as the power source is restored. Although the timer mode is cancelled, the weekly timer, peak cut timer and silent
mode timer operate according to the following contents:
• When the clock function is valid: It functions according to set contents.
• When the clock function is invalid: If the clock function is set once more, and the setting of weekly timer, peak cut timer
and silent mode timer is changed to "Valid" using the function setting of remote control, it functions according to set
contents.
● Content memorized with the power failure compensation are as follows.
Note (1) Items (f) and (g) are memorized regardless whether the power failure compensation is effective or not while the setting of silent mode is cancelled
regardless whether the power failure compensation is effective or not.
(a) At power failure – Operating/stopped
If it had been operating under the off timer mode, sleep timer mode, the state of stop is memorized.
(b) Operation mode
(c) Air flow volume mode
(d) Room temperature setting
(e) Louver auto swing/stop
However, the stop position (4-position) is cancelled so that it returns to Position (1).
(f)
"Remote control function items" which have been set with the administrator or installation function settings
("Indoor function items" are saved in the memory of indoor unit.)
(g) Weekly timer, peak-cut timer or silent mode timer settings
(h) Remote control function setting
172
-
-