Mitsubishi SCM40ZS-S Technical Manual page 222

Inverter multi-split system residential air-conditioners
Table of Contents

Advertisement

(ii) Outdoor unit
Remote control
Indoor control PCB
Green
Error code Red LED Red LED
LED
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
flashing
Keeps
Stays OFF
flashing
Keeps
Stay OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Keeps
Stays OFF
flashing
Notes (1) * mark in the description of trouble means that, in ordinary diagnosis, it cannot identify the cause definitely, and, if the trouble is repaired by replacing the
part, it is judged consequently that the replaced part was defective.
(2) This LED is installed on model SCM50ZS-S.
Outdoor
main PCB
Location of trouble
Red
LED (2)
Installation, operation status • Higher outdoor heat exchanger temperature
Outdoor heat exchanger
2-time
• Defective outdoor heat exchanger temperature sensor
temperature sensor
flash
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Installation, operation status • Higher discharge temperature
Discharge pipe temperature
5-time
• Defective discharge pipe temperature sensor
sensor
flash
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Outdoor heat exchanger
• Defective outdoor heat exchanger temperature sensor, broken wire or poor
8-time
temperature sensor
connector connection
flash
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Outdoor air temperature
• Defective outdoor air temperature sensor, broken wire or poor connector
8-time
sensor
connection
flash
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Discharge pipe temperature
• Defective discharge pipe temperature sensor, broken wire or poor connector
8-time
sensor
connection
flash
Outdoor main PCB
*• Defective outdoor main PCB (Defective temperature sensor input circuit)?
Outdoor main PCB,
• Current cut (Anomalous compressor over-current)
1-time
compressor
flash
Installation, operation status • Service valve closing operation
Outdoor main PCB
• Anomalous outdoor main PCB commuication
4-time
flash
Outdoor sub PCB
• Anomalous outdoor sub PCB commuication
2-time
Outdoor sub PCB
• Defective active filter
flash
Fan motor
• Defective fan motor
ON
Outdoor main PCB
• Defective outdoor main PCB
1-time
Power transistor error
• Power transistor error
flash
(outdoor main PCB)
• Defective suction pipe temperature sensor, broken wire or poor connector
Outdoor suction pipe sensor
8-time
connection
flash
Outdoor sub PCB
• Defective outdoor sub PCB (Defective temperature sensor input circuit)?
Operation status
• Shortage in refrigerant quantity
2-time
flash
Installation status
• Service valve closing operation
• Overload operation
3-time
• Overcharge
• Current safe stop
flash
• Compressor locking
2-time
Compressor, outdoor main
• Anomalous compressor startup
flash
PCB
7-time
Compressor
• Anomalous compressor rotor lock
flash
-
Description of trouble
221
-
'16 • SCM-T-199
Reference
Repair method
page
Repair
Replacement, repair
of temperature
260
sensor
Replacement of
PCB
Repair
Replacement, repair
of temperature
261
sensor
Replacement of
PCB
Replacement, repair
of temperature
sensor
262
Replacement of
PCB
Replacement, repair
of temperature
sensor
263
Replacement of
PCB
Replacement, repair
of temperature
sensor
264
Replacement of
PCB
Replacement of
PCB
265• 266
Repair
Replacement of
267
PCB
Repair
268
PCB replacement
Replacement
269
Replacement of
270
PCB
Replacement, repair
of temperature
sensor
271
Replacement of
PCB
Repair
272
Service valve
opening check
Replacement
273
Replacement
274
Replacement
275

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents