(b) Swing
Flap moves in upward and downward directions continuously.
S In COOL, DRY operation
Approx.
20°
Approx. 59°
(c) Memory flap
When you press the AIR FLOW (UP/DOWN) button once while the flap is operating, it stops swinging at an angle. Since this
angle is memorized in the microcomputer, the flap will automatically be set at this angle when the next operation is started.
(d) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.

(7) Timer operation

(a) Comfortable timer setting (ON timer)
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in auto
mode operation is selected, the comfortable timer starts and determines the starting time of next operation based on the initial
value of 15 minutes and the relationship between the room temperature at the setting time (temperature of room temperature
sensor) and the setting temperature.
(b) Sleep timer operation
Pressing the SLEEP button causes the temperature to be controlled with respect to the set temperature.
(c) OFF timer operation
The Off timer can be set at a specific time (in 10-minute units) within a 24-hour period.
(8) Determining the operating mode
The cooling and heating operating modes are the wireless remote control mode that have been previously determined.
If a mode differing from these is selected after this, the selected mode will appear in the display of the wireless remote control,
but only the fan will operate.
First operation
Example
Selected mode
Remote control display
1
Cooling
COOL
Heating
HEAT
2
Note (1) If the display shows heating and the operation is fan, Hot keep will operate.
Example of operating pattern
Cooling
switch
A unit
ON
Heating
B unit
switch
Operation Operation
Approx. 35°
Operation
Selected mode
COOL
Heating
HEAT
Cooling
COOL
FAN
ON
S In HEAT operation
Approx. 65°
Second operation
Remote control display
Operation
HEAT
FAN
(1)
COOL
FAN
Heating
FAN
switch
ON
Cooling
COOL
switch
ON
Operation Operation
164
-
-
'16 • SCM-T-199
Notes
• Different mode is
only fan operation.
HEAT
Heating
HEAT
switch
ON
Operation
Note (1)   indicates currect operation.