Error code
E11
Remote control:
1. Applicable model
All models
2. Error detection method
IU address has been set using
the "Master IU address set"
function of remote control.
3. Condition of error displayed
Same as above
4. Presumable cause
Same as above
Note:
LED
Green
Red
Keeps flashing Keeps flashing
Indoor
Outdoor
–
Stays OFF
5. Troubleshooting
Diagnosis
E11 occurs
Is "Master IU
address set" function of remote
control used?
In case the wiring is below and "Master IU address
set" is used, E11 is appeared.
IU
IU
R/C
254
-
Content
Address setting error of
indoor units
YES
IU
-
'16 • SCM-T-199
Countermeasure
• In cases of RC-EX1A
Menu → Next
→ IU settings → Select IU
• In cases of RC-E5
Return address No. to
"IU ..." using [ ▲ ] or
[ ▲ ] button.